Product Model
RIF-1-RPT-LDP-24DC/1IC

Selling Points
- 1High Switch-On Currents: Supports up to 130 A peak and 80 A continuous current.
- 2Robust Design: Preassembled with a relay base, power contact relay, and interference suppression module.
- 3Reliable Performance: 1 N/O contact with a maximum switching voltage of 250 V AC/DC.
- 4Easy Installation: Push-in connection for quick and secure terminal block mounting.
- 5Comprehensive Safety: Meets UL 508 and DIN EN 61810-3 standards for safety and reliability.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Notes on operation | FBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in bridge for the output side (11/21) | Product type | Relay Module |
Product family | RIFLINE complete | Application | high inrush currents |
Operating mode | 100% operating factor | Mechanical service life | 3x 10 |
Date of last data management | 15.10.2024 | Article revision | 05 |
Insulation | Safe isolation, reinforced insulation | Overvoltage category | III |
Pollution degree | 2 | Maximum power dissipation for nominal condition | 0.43 W |
Test voltage (Winding/contact) | 4 kV AC (50 Hz, 1 min., winding/contact) | Rated insulation voltage | 250 V AC |
Rated surge voltage | 6 kV | Nominal input voltage U | 24 V DC |
Input voltage range | 19.2 V DC ... 33.6 V DC (20 °C) | Input voltage range in reference to U | see diagram |
Drive and function | monostable | Drive (polarity) | polarized |
Typical input current at U | 18 mA | Typical response time | 8 ms |
Typical release time | 10 ms | Coil voltage | 24 V DC |
Protective circuit | Freewheeling diode; Freewheeling diode | Operating voltage display | Yellow LED |
Contact switching type | 1 N/O contact | Type of switch contact | Single contact |
Contact material | AgSnO | Maximum switching voltage | 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
Minimum switching voltage | 12 V (100 mA) | Limiting continuous current | 6 A
10 A (Value is permissible if connections 11 and 21, as well as connections 14 and 24 are bridged.) |
Maximum inrush current | 80 A (20 ms)
130 A (peak, at capacitive load, 230 V AC, 24 μF) | Min. switching current | 100 mA (12 V DC) |
Interrupting rating (ohmic load) max. | 264 W (at 24 V DC, observe contact derating)
58 W (at 48 V DC)
48 W (at 60 V DC)
50 W (at 110 V DC)
80 W (at 220 V DC)
2750 VA (at 250 V AC, observe contact derating) | Switching capacity min. | 1200 mW |
Utilization category CB Scheme (IEC 60947-5-1) | AC15, 6 A/250 V (N/O contact)
DC13, 2 A/24 V (N/O contact) | Connection method | Push-in connection |
Stripping length | 8 mm | Conductor cross section rigid | 0.14 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block) | Conductor cross section AWG | 26 ... 16 (solid)
26 ... 16 (flexible) |
Diameter | 3.2 mm | Width | 16 mm |
Height | 96 mm | Depth | 75 mm |
Color | gray (RAL 7042) | Degree of protection (Relay base) | IP20 (Relay base) |
Degree of protection (Relay) | RT III (Relay) | Degree of protection (Installation location) | ≥ IP54 (Installation location) |
Ambient temperature (operation) | -40 °C ... 70 °C | Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 2000 m | Identification | ISA-S71.04. G3 Harsh Group
EN 60068-2-60 |
Standards/regulations | IEC 60947-5-1 | Mounting type | DIN rail mounting |
Assembly note | in rows with zero spacing | Mounting position | any |
Specifications may be subject to change without notice