Selling Points

  • 1High-Quality Industrial Control: Designed for industrial control equipment, ensuring reliability and precision.
  • 224V DC Input: Compatible with 24V DC power, ideal for various industrial applications.
  • 3Forcedly Guided Contacts: Meets DIN EN 50205 standards, ensuring safe and reliable switching.
  • 4Durable Construction: Built with AgNi contacts, offering high switching voltage and current capacity.
  • 5Easy Installation: Pre-assembled with screw connection, simplifying integration into your system.
Product Details
RIF-1-RSC-LDP-24DC/2X21/FG
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Relay Module
Product family
RIFLINE complete
Application
Forcibly guided contacts
Operating mode
100% operating factor
Mechanical service life
approx. 10
B
600000 Cycles (AC1; 250 V / 6 A; 1 NO) 900000 Cycles (AC1; 250 V / 3 A; 1 NO) 1800000 Cycles (AC1; 250 V / 1,5 A; 1 NO) 300000 Cycles (DC13; 24 V / 3 A; 1 NO) 1000000 Cycles (DC13; 24 V / 1,5 A; 1 NO) 3000000 Cycles (DC13; 24 V / 0,75 A; 1 NO)
Date of last data management
21.08.2024
Article revision
03
Insulation
Safe isolation between input and output Basic insulation between the changeover contacts
Overvoltage category
III
Pollution degree
2
Maximum power dissipation for nominal condition
0.72 W
Test voltage (Winding/contact)
4 kV
Test voltage ()
1.5 kV
Test voltage (Changeover contact/changeover contact)
2.5 kV
Rated insulation voltage
250 V AC (Input/output)
Rated surge voltage
6 kV (Input/output) 4 kV (between the changeover contacts)
Current
10 A (RT28-32)
Voltage
500 V (SCPD)
Short-circuit current
1 kA (conditional short-circuit current)
Nominal operating voltage U
24 V DC
Input voltage range
20.4 V DC ... 28.8 V DC (20 °C)
Input voltage range in reference to U
see diagram
Drive and function
monostable
Drive (polarity)
polarized
Typical input current at U
30 mA
Typical response time
15 ms
Typical release time
10 ms
Coil voltage
24 V DC
Protective circuit
Freewheeling diode
Operating voltage display
Yellow LED
Contact switching type
2 changeover contacts, forcibly actuated
Type of switch contact
Single contact
Contact material
AgSnO
Maximum switching voltage
250 V AC/DC
Limiting continuous current
6 A
Interrupting rating (ohmic load) max.
144 W (24 V DC) 58 W (48 V DC) 54 W (60 V DC) 55 W (110 V DC) 55 W (220 V DC) 1500 VA (250 V AC)
Utilization category CB Scheme (IEC 60947-5-1)
AC15, 3 A/240 V (N/O contact)
Connection method
Screw connection
Stripping length
8 mm
Conductor cross section rigid
0.5 mm² ... 4 mm²
Conductor cross-section rigid (2 conductors with same cross section)
0.5 mm² ... 2.5 mm²
Conductor cross section flexible
0.5 mm² ... 4 mm² 0.5 mm² ... 4 mm² (Ferrule with plastic sleeve)
Conductor cross section flexible (2 conductors with same cross section)
0.5 mm² ... 2.5 mm² 0.5 mm² ... 1.5 mm² (TWIN ferrule with plastic sleeve)
Conductor cross section AWG
20 ... 10 (solid) 20 ... 12 (flexible)
Tightening torque
0.5 Nm ... 0.6 Nm
Width
16 mm
Height
90 mm
Depth
75 mm
Color
gray (RAL 7042)
Flammability rating according to UL 94
V2 (Housing)
Degree of protection (Relay base)
IP20 (Relay base)
Degree of protection (Relay)
RT I (Relay)
Ambient temperature (operation)
-25 °C ... 60 °C
Ambient temperature (storage/transport)
-25 °C ... 85 °C
Altitude
≤ 2000 m
Certificate
CE-compliant
Certificate
UKCA-compliant
Identification
ISA-S71.04. G3 Harsh Group EN 60068-2-60
Standards/regulations
IEC 60947-5-1 IEC 61810-3
Standards/regulations
DIN EN 60947-5-1
Mounting type
DIN rail mounting
Assembly note
in rows with zero spacing
Mounting position
any

Specifications may be subject to change without notice