Product Model
RIF-4-RPT-LDP-24DC/3X21

Selling Points
- 1Universal application with 3 changeover contacts.
- 224V DC input voltage with a range of 20.4V to 26.4V DC.
- 3Maximum switching voltage of 440V AC and 250V DC.
- 4Basic insulation with an overvoltage category of III and pollution degree of 2.
- 5Mechanical service life of approximately 107 cycles and a maximum power dissipation of 1.34W.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | Relay Module | Product family | RIFLINE complete |
Application | Universal | Operating mode | 100% operating factor |
Mechanical service life | approx. 10 | Date of last data management | 22.08.2024 |
Article revision | 09 | Insulation | Basic insulation |
Overvoltage category | III | Pollution degree | 2 |
Maximum power dissipation for nominal condition | 1.34 W | Test voltage (Winding/contact) | 2.5 kV |
Test voltage (Contact/contact) | 2.5 kV | Rated insulation voltage | 250 V AC |
Rated surge voltage | 4 kV | Nominal input voltage U | 24 V DC |
Input voltage range | 20.4 V DC ... 26.4 V DC (20 °C) | Input voltage range in reference to U | see diagram |
Drive and function | monostable | Drive (polarity) | polarized |
Typical input current at U | 56 mA | Typical response time | 20 ms |
Typical release time | 20 ms | Coil voltage | 24 V DC |
Protective circuit | Freewheeling diode | Operating voltage display | Yellow LED |
Contact switching type | 3 changeover contacts | Type of switch contact | Single contact |
Contact material | AgNi | Maximum switching voltage | 440 V AC
250 V DC |
Minimum switching voltage | 10 V (24 mA) | Limiting continuous current | 10 A (see diagram) |
Maximum inrush current | 50 A (20 ms, N/O contacts) | Min. switching current | 10 mA (24 V) |
Interrupting rating (ohmic load) max. | 240 W (24 V DC)
124 W (48 V DC)
108 W (60 V DC)
52 W (110 V DC)
70 W (220 V DC)
2500 VA (250 V AC)
4000 VA (440 V AC) | 3-phase motor load | 1500 W |
Motor load according to UL 508 | 1/3 HP, 120 V AC (single-phase AC motor)
1/2 HP, 240 V AC (single-phase AC motor)
1/2 HP, 240 V AC (three-phase induction motor) | Utilization category CB Scheme (IEC 60947-5-1) | AC15, 1.5 A/240 V (N/O contact)
DC13, 2 A/240 V (N/O contact) |
Connection method | Push-in connection | Stripping length | 8 mm |
Conductor cross section rigid | 0.14 mm² ... 1.5 mm² | Conductor cross section flexible | 0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block) |
Conductor cross section AWG | 26 ... 16 (solid)
26 ... 16 (flexible) | Connection method | Push-in connection |
Stripping length | 10 mm | Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm²
0.14 mm² ... 2.5 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block) | Conductor cross section AWG | 26 ... 14 (solid)
26 ... 14 (flexible) |
Diameter | 3.2 mm | Width | 43 mm |
Height | 111 mm | Depth | 90 mm |
Color | gray (RAL 7042) | Flammability rating according to UL 94 | V2 (Housing) |
Degree of protection (Relay base) | IP20 (Relay base) | Degree of protection (Relay) | RT I (Relay) |
Ambient temperature (operation) | -40 °C ... 60 °C | Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Identification | ISA-S71.04. G3 Harsh Group
EN 60068-2-60 | Standards/regulations | IEC 60947-5-1 |
Mounting type | DIN rail mounting | Assembly note | in rows with zero spacing |
Mounting position | any |
Specifications may be subject to change without notice