Product Model

RIF-4-RSC-LDP-24DC/3X1

In Stock
Last updated: 2025/4/21
Phoenix Contact RIF-4-RSC-LDP-24DC/3X1

Selling Points

  • 13 N/O Contacts: Reliable and efficient switching solution.
  • 224 V DC Input: Compatible with a wide range of DC power systems.
  • 3High Switching Capacity: Handles up to 1.5 A at 24 V AC and 1 A at 120 V DC.
  • 4AgNi Contact Material: Durable and resistant to wear and tear.
  • 5UL 508 Approval: Meets stringent safety standards for industrial applications.
Product Details
RIF-4-RSC-LDP-24DC/3X1
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Relay Module
Product family
RIFLINE complete
Application
Universal
Operating mode
100% operating factor
Mechanical service life
approx. 10
Date of last data management
31.10.2024
Article revision
03
Insulation
Basic insulation
Overvoltage category
III
Pollution degree
2
Maximum power dissipation for nominal condition
1.68 W
Test voltage (Winding/contact)
2.5 kV
Test voltage (Contact/contact)
2.5 kV
Rated insulation voltage
250 V AC
Rated surge voltage
4 kV
Nominal input voltage U
24 V DC
Input voltage range
20.4 V DC ... 26.4 V DC (20 °C)
Input voltage range in reference to U
see diagram
Drive and function
monostable
Typical input current at U
70 mA
Typical response time
20 ms
Typical release time
20 ms
Coil voltage
24 V DC
Protective circuit
Freewheeling diode
Operating voltage display
Yellow LED
Contact switching type
3 N/O contacts
Type of switch contact
Single contact
Contact material
AgNi
Maximum switching voltage
440 V AC 250 V DC
Minimum switching voltage
10 V (24 mA)
Limiting continuous current
10 A (see diagram)
Maximum inrush current
50 A (20 ms, N/O contacts)
Min. switching current
10 mA (24 V)
Interrupting rating (ohmic load) max.
240 W (24 V DC) 480 W (48 V DC) 600 W (60 V DC) 660 W (110 V DC) 183 W (220 V DC) 2500 VA (250 V AC) 4000 VA (440 V AC)
Motor load according to UL 508
1/3 HP, 120 V AC (single-phase AC motor) 1/2 HP, 240 V AC (single-phase AC motor) 1/2 HP, 240 V AC (three-phase induction motor)
Utilization category CB Scheme (IEC 60947-5-1)
AC15, 1.5 A/240 V (N/O contact) DC13, 2 A/240 V (N/O contact)
Connection method
Screw connection
Stripping length
8 mm
Conductor cross section rigid
0.5 mm² ... 4 mm²
Conductor cross-section rigid (2 conductors with same cross section)
0.5 mm² ... 2.5 mm²
Conductor cross section flexible
0.5 mm² ... 4 mm² 0.5 mm² ... 4 mm² (Ferrule with plastic sleeve)
Conductor cross section flexible (2 conductors with same cross section)
0.5 mm² ... 2.5 mm² 0.5 mm² ... 1.5 mm² (TWIN ferrule with plastic sleeve)
Conductor cross section AWG
20 ... 10 (solid) 20 ... 12 (flexible)
Tightening torque
0.5 Nm ... 0.6 Nm
Width
44 mm
Height
96 mm
Depth
91 mm
Color
gray (RAL 7042)
Flammability rating according to UL 94
V2 (Housing)
Degree of protection (Relay base)
IP20 (Relay base)
Degree of protection (Relay)
RT I (Relay)
Ambient temperature (operation)
-40 °C ... 60 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Identification
ISA-S71.04. G3 Harsh Group EN 60068-2-60
Standards/regulations
DIN EN 50178
Mounting type
DIN rail mounting
Assembly note
in rows with zero spacing
Mounting position
any

Specifications may be subject to change without notice