Product Model

TRIO-DIODE/48DC/2X10/1X20

In Stock
Last updated: 2025/4/17
Phoenix Contact TRIO-DIODE/48DC/2X10/1X20

Selling Points

  • 1Redundant Power Supply: Ensures continuous system operation with automatic failover in case of primary unit failure.
  • 2DIN Rail Mounting: Easy installation on standard DIN rail systems for efficient space utilization.
  • 3High Reliability: Designed for systems requiring high operational reliability, with a robust IP20 protection rating.
  • 4Flexible Current Outputs: Provides 2x10A and 1x20A outputs to meet various load requirements.
  • 5Long-Term Availability: Supports long-term system availability with permanent monitoring of redundancy status.
Product Details
TRIO-DIODE/48DC/2X10/1X20
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Nominal input voltage range
48 V DC
Input voltage range
30 V DC ... 56 V DC
Voltage type of supply voltage
DC
Reverse polarity protection
< yes60 V
Nominal input current (I
2x 10 A (-25 °C ... 55 °C) 1x 20 A (-25 °C ... 55 °C)
Maximum current I
2x 15 A (-25 °C ... 40 °C) 1x 30 A (-25 °C ... 40 °C)
Transient surge protection
Varistor
Voltage drop, input/output
approx. 0.65 V
Efficiency
> 97 %
Nominal output voltage
U
Nominal output current (I
20 A (Increasing power) 10 A (Redundancy)
Derating
55 °C ... 70 °C (2.5 %/K)
Maximum no-load power dissipation
7 W (I
Power loss nominal load max.
14 W (I
Connection in series
no
Output description
Contact closed when U
Maximum switching voltage
30 V AC/DC
Maximum inrush current
≤ 100 mA (short-circuit-proof)
Connection method
Screw connection
Conductor cross section, rigid min.
0.2 mm²
Conductor cross section, rigid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
14
Stripping length
9 mm
Screw thread
M2,5
Tightening torque, min
0.4 Nm
Tightening torque max
0.5 Nm
Connection method
Screw connection
Conductor cross section, rigid min.
0.5 mm²
Conductor cross section, rigid max.
6 mm²
Conductor cross section flexible min.
0.5 mm²
Conductor cross section flexible max.
4 mm²
Conductor cross section AWG min.
20
Conductor cross section AWG max.
10
Stripping length
14 mm
Screw thread
M3
Tightening torque, min
0.5 Nm
Tightening torque max
0.6 Nm
Conductor cross section, rigid min.
0.2 mm²
Conductor cross section, rigid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
14
Screw thread
M2,5
Tightening torque, min
0.4 Nm
Tightening torque max
0.5 Nm
Types of signaling
LED Relay contact
Status display
LED redundancy OK
Note on status display
U
Insulation voltage input, output / housing
500 V
Product type
Redundancy module
Product family
TRIO DIODE
MTBF (IEC 61709, SN 29500)
> 10000000 h (40 °C)
LED
yes
Article revision
02
Protection class
III
Degree of pollution
2
Width
32 mm
Height
130 mm
Depth
115 mm
Horizontal pitch
1.8 Div.
Installation distance right/left
0 mm / 0 mm
Installation distance top/bottom
50 mm / 50 mm
Mounting type
DIN rail mounting
Assembly note
alignable: horizontally 0 mm, vertically 50 mm
Mounting position
horizontal DIN rail NS 35, EN 60715
Housing material
Metal
Housing material
Steel sheet, zinc-plated
Type of housing
Steel sheet, zinc-plated
Side element version
Aluminum
Degree of protection
IP20
Ambient temperature (operation)
-25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Climatic class
3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)
≤ 95 % (at 25 °C, non-condensing)
Shock
15g in all directions in acc. with IEC 60068-2-27
Vibration (operation)
15 Hz ... 150 Hz, 2.3g t
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
EN 50178/VDE 0160 (PELV)
Standard - Electrical safety
EN 60950-1/VDE 0805 (SELV)
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment
EN 50178
Standard – Safety extra-low voltage
IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolation
DIN VDE 0100-410
UL approvals
UL/C-UL listed UL 508 UL/C-UL Recognized UL 60950-1
SIL in accordance with IEC 61508
0
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Low Voltage Directive
Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission
EN 61000-6-3 EN 61000-6-4
EMC requirements for noise immunity
EN 61000-6-1 EN 61000-6-2
Standards/regulations
EN 61000-4-2
Contact discharge
6 kV (Test Level 3)
Discharge in air
8 kV (Test Level 3)
Comments
Criterion B
Standards/regulations
EN 61000-4-3
Frequency range
80 MHz ... 1 GHz
Test field strength
10 V/m (Test Level 3)
Frequency range
1 GHz ... 2 GHz
Test field strength
10 V/m (Test Level 3)
Frequency range
2 GHz ... 3 GHz
Test field strength
10 V/m (Test Level 3)
Comments
Criterion A
Standards/regulations
EN 61000-4-4
Input
2 kV (Test Level 3 - asymmetrical)
Output
2 kV (Test Level 3 - asymmetrical)
Comments
Criterion B
Standards/regulations
EN 61000-4-5
Input
0.5 kV (Test Level 1 - symmetrical) 0.5 kV (Test Level 1 - asymmetrical)
Output
0.5 kV (Test Level 1 - symmetrical) 0.5 kV (Test Level 1 - asymmetrical)
Comments
Criterion B
Standards/regulations
EN 61000-4-6
I/O/S
asymmetrical
Frequency range
0.15 MHz ... 80 MHz
Comments
Criterion A
Voltage
10 V (Test Level 3)
Standards/regulations
EN 61000-6-3
Radio interference voltage in acc. with EN 55011
EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011
EN 55011 (EN 55022) Class B, area of application: Industry and residential
Criterion A
Normal operating behavior within the specified limits.
Criterion B
Temporary impairment to operational behavior that is corrected by the device itself.

Specifications may be subject to change without notice