Phoenix Contact TRIO-PS-2G/1AC/24DC/5/B+D

Selling Points

  • 1Ensures regulated output voltage even in voltage fluctuations.
  • 2Operates from -25°C to +70°C, with startup at -40°C.
  • 3Electrically and mechanically robust, with high electric strength and vibration resistance.
  • 4Simplifies installation with a push-in connection for DIN rail mounting.
  • 5Allows connection in parallel for redundancy and increased capacity.
Product Details
TRIO-PS-2G/1AC/24DC/5/B+D
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Network type
Star network
Nominal input voltage range
100 V AC ... 240 V AC
Input voltage range
100 V AC ... 240 V AC -15 % ... +10 %
Derating
< 100 V AC (1 %/V)
Input voltage range AC
85 V AC ... 264 V AC
Switch-on voltage
>
Electric strength, max.
≤ 300 V AC 15 s
Typical national grid voltage
120 V AC 230 V AC
Voltage type of supply voltage
AC/DC
Inrush current
≤ 16 A (typical)
Inrush current integral (I
< 0.6 A
Inrush current limitation
typ. 16 A (after 1 ms)
AC frequency range
50 Hz ... 60 Hz ±5 Hz
Frequency range (f
50 Hz ... 60 Hz ±10 %
Mains buffering time
typ. 20 ms (120 V AC) typ. 100 ms (230 V AC)
Current consumption
2.2 A (100 V AC) 1.9 A (120 V AC) 1.1 A (230 V AC) 1.1 A (240 V AC)
Nominal power consumption
272 VA
Protective circuit
Transient surge protection; Varistor
Power factor (cos phi)
0.5
Typical response time
< 1 s
Input fuse
6.3 A (internal (device protection))
Recommended breaker for input protection
6 A ... 16 A (Characteristics B, C, D, K)
Discharge current to PE
< 0.25 mA
Nominal input voltage range
110 V DC ... 250 V DC
Input voltage range
99 V DC ... 275 V DC
Derating
< 110 V DC (1 %/V)
Switch-on voltage
≥ 85 V DC
Shut-down voltage
< 60 V DC
Voltage type of supply voltage
AC/DC
Mains buffering time
> 100 ms (230 V AC)
Current consumption
1.4 A (110 V DC) 0.6 A (250 V DC)
Efficiency
> 89 % (for 230 V AC and nominal values)
Output characteristic
U/I with dynamic load reserve
Nominal output voltage
24 V DC ±1 %
Setting range of the output voltage (U
24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (I
5 A
Dynamic Boost (I
7.5 A (5 s)
Derating
> 60 °C ... 70 °C (2.5 %/K)
Feedback voltage resistance
≤ 35 V DC
Protection against overvoltage at the output (OVP)
≤ 30 V DC
Control deviation
< 1 % (change in load, static 10 % ... 90 %) < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz) < 0.1 % (change in input voltage ±10 %)
Residual ripple
< 50 mV
Output power
120 W 180 W
Maximum no-load power dissipation
< 1 W
Power loss nominal load max.
< 16 W
Rise time
≤ 12 ms (U
Connection in parallel
yes, for redundancy and increased capacity
Connection in series
yes
Maximum switching voltage
30 V AC/DC
Continuous load current
100 mA
Connection method
Push-in connection
Conductor cross section, rigid min.
0.2 mm²
Conductor cross section, rigid max.
4 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
12
Stripping length
10 mm
Connection method
Push-in connection
Conductor cross section, rigid min.
0.2 mm²
Conductor cross section, rigid max.
4 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
12
Stripping length
8 mm
Connection method
Push-in connection
Conductor cross section, rigid min.
0.2 mm²
Conductor cross section, rigid max.
1.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
1.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
16
Stripping length
8 mm
Types of signaling
LED Floating signal contact
Signalization designation
DC OK
Status display
“DC OK” LED
Color
green
Number of phases
1.00
Insulation voltage input/output
3 kV AC (type test) 1.5 kV AC (routine test)
Product type
Power supply
Product family
TRIO POWER
MTBF (IEC 61709, SN 29500)
> 3380000 h (25 °C) > 1970000 h (40 °C) > 900000 h (60 °C)
Article revision
02
Protection class
II (in closed control cabinet)
Degree of pollution
2
Width
35 mm
Height
130 mm
Depth
115 mm
Installation distance right/left
0 mm / 0 mm
Installation distance top/bottom
50 mm / 50 mm
Mounting type
DIN rail mounting
Assembly note
alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
Mounting position
horizontal DIN rail NS 35, EN 60715
With protective coating
no
Flammability rating according to UL 94 (housing / terminal blocks)
V0
Housing material
Plastic
Type of housing
Polycarbonate
Hood version
Polycarbonate
Degree of protection
IP20
Ambient temperature (operation)
-25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Ambient temperature (start-up type tested)
-25 °C
Maximum altitude
≤ 5000 m (> 2000 m, observe derating)
Climatic class
3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)
≤ 95 % (at 25 °C, non-condensing)
Shock
18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)
< 25 Hz, amplitude ±1.6 mm (according to DNV GL CG-0339) 15 Hz ... 150 Hz, 4g, 90 min.
Rail applications
EN 50121-4
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
EN 50178/VDE 0160 (PELV)
Standard – Limitation of mains harmonic currents
EN 61000-3-2
Standard - Electrical safety
IEC 62368-1 (SELV)
Standard – Safety extra-low voltage
IEC 62368-1 (SELV) und EN 60204-1 (PELV)
Standard - Safe isolation
DIN VDE 0100-410
Standard - Safety of transformers
EN 61558-2-16 (air clearances and creepage distances only)
Approval - requirement of the semiconductor industry with regard to mains voltage dips
Semi F47-0706
Shipbuilding approval
DNV GL (EMC B) IEC 60945
UL approvals
UL Listed UL 508 UL/C-UL Recognized UL 60950-1
SIL in accordance with IEC 61508
0
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Low Voltage Directive
Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission
EN 61000-6-3 EN 61000-6-4
EMC requirements for noise immunity
EN 61000-6-1 EN 61000-6-2
Noise emission
EN 55011 (EN 55022)
Standards/regulations
EN 61000-4-2
Contact discharge
6 kV (Test Level 4)
Discharge in air
8 kV (Test Level 4)
Comments
Criterion A
Standards/regulations
EN 61000-4-3
Frequency range
80 MHz ... 1 GHz
Test field strength
10 V/m (Test Level 3)
Frequency range
1 GHz ... 2 GHz
Test field strength
10 V/m (Test Level 3)
Frequency range
2 GHz ... 3 GHz
Test field strength
10 V/m (Test Level 3)
Comments
Criterion A
Standards/regulations
EN 61000-4-4
Input
4 kV (Test Level 4 - asymmetrical)
Output
2 kV (Test Level 3 - asymmetrical)
Signal
1 kV (Test Level 2 - asymmetrical)
Comments
Criterion A
Standards/regulations
EN 61000-4-5
Input
1 kV (Test Level 2 - symmetrical) 2 kV (Test Level 3 - asymmetrical)
Output
0.5 kV (Test Level 1 - symmetrical) 0.5 kV (Test Level 1 - asymmetrical)
Signal
1 kV (Test Level 2 - asymmetrical)
Comments
Criterion B
Standards/regulations
EN 61000-4-6
Input/Output
asymmetrical
Frequency range
0.15 MHz ... 80 MHz
Comments
Criterion A
Voltage
10 V (Test Level 3)
Standards/regulations
EN 61000-6-3
Radio interference voltage in acc. with EN 55011
EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011
EN 55011 (EN 55022) Class B, area of application: Industry and residential
Criterion A
Normal operating behavior within the specified limits.
Criterion B
Temporary impairment to operational behavior that is corrected by the device itself.

Specifications may be subject to change without notice