Product Model
TRIO-PS-2G/3AC/24DC/20

Selling Points
- 1Robust Design: Built with a slim and robust design for reliable operation in harsh industrial environments.
- 2Dynamic Boost: Ensures reliable starting of heavy loads with a dynamic boost of 1.5 times the nominal current for 5 seconds.
- 3Wide Input Voltage Range: Compatible with input voltages from 3x 400 V AC to 500 V AC, making it versatile for various industrial settings.
- 4Efficient Operation: Achieves efficiency of >93% at 400 V AC, reducing energy waste and increasing system availability.
- 5Easy Installation: Features push-in connection technology for fast and tool-free wiring, simplifying installation and reducing downtime.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Network type | Star network | Nominal input voltage range | 3x 400 V AC ... 500 V AC
2x 400 V AC ... 500 V AC |
Input voltage range | 3x 400 V AC ... 500 V AC -20 % ... +15 %
2x 400 V AC ... 500 V AC -10 % ... +15 % | Input voltage range AC | 3x 320 V AC ... 575 V AC |
Typical national grid voltage | 3x 400 V AC
3x 480 V AC | Voltage type of supply voltage | AC |
Inrush current | ≤ 22 A (typical) | Inrush current integral (I | ≤ 0.5 A |
AC frequency range | 50 Hz ... 60 Hz | Mains buffering time | typ. 10 ms (400 V AC)
typ. 20 ms (500 V AC) |
Current consumption | 3x 1.2 A (400 V AC)
3x 1 A (500 V AC)
2x 2.3 A (400 V AC)
2x 1.9 A (500 V AC) | Nominal power consumption | 822.2 VA |
Protective circuit | Transient surge protection; Varistor | Power factor (cos phi) | 0.63 |
Typical response time | < 1 s | Input fuse | 3.15 A (internal (device protection), slow-blow) |
Recommended breaker for input protection | 6 A ... 16 A (Characteristics B, C, D, K) | Discharge current to PE | < 3.5 mA
< (550 V AC, 60 Hz) |
Efficiency | > 93 % (400 V AC)
500 V AC | Output characteristic | U/I with dynamic load reserve |
Nominal output voltage | 24 V DC ±1 % | Setting range of the output voltage (U | 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted) |
Nominal output current (I | 20 A | Dynamic Boost (I | 30 A (5 s) |
Derating | > 60 °C ... 70 °C (2.5 %/K) | Protection against overvoltage at the output (OVP) | ≤ 30 V DC |
Control deviation | < 1 % (change in load, static 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %) | Residual ripple | ≤ 20 mV |
Short-circuit-proof | yes | No-load proof | yes |
Output power | 480 W
720 W | Maximum no-load power dissipation | < 1.2 W (400 V AC) |
Power loss nominal load max. | < 38 W (480 V AC) | Rise time | ≤ 120 ms (U |
Connection in parallel | yes, for redundancy and increased capacity | Connection in series | yes |
Continuous load current | 100 mA | Default | closed |
Digital | 30 V AC 30 V DC 100 mA | Connection method | Push-in connection |
Conductor cross section, rigid min. | 0.2 mm² | Conductor cross section, rigid max. | 4 mm² |
Conductor cross section flexible min. | 0.2 mm² | Conductor cross section flexible max. | 2.5 mm² |
Single conductor/terminal point, stranded, with ferrule, min. | 0.2 mm² | Single conductor/terminal point, stranded, with ferrule, max. | 2.5 mm² |
Conductor cross section AWG min. | 24 | Conductor cross section AWG max. | 12 |
Stripping length | 10 mm | Connection method | Push-in connection |
Conductor cross section, rigid min. | 0.2 mm² | Conductor cross section, rigid max. | 10 mm² |
Conductor cross section flexible min. | 0.2 mm² | Conductor cross section flexible max. | 6 mm² |
Single conductor/terminal point, stranded, with ferrule, min. | 0.2 mm² | Single conductor/terminal point, stranded, with ferrule, max. | 6 mm² |
Conductor cross section AWG min. | 24 | Conductor cross section AWG max. | 8 |
Stripping length | 15 mm | Connection method | Push-in connection |
Conductor cross section, rigid min. | 0.2 mm² | Conductor cross section, rigid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² | Conductor cross section flexible max. | 1.5 mm² |
Single conductor/terminal point, stranded, with ferrule, min. | 0.2 mm² | Single conductor/terminal point, stranded, with ferrule, max. | 1.5 mm² |
Conductor cross section AWG min. | 24 | Conductor cross section AWG max. | 16 |
Stripping length | 8 mm | Types of signaling | LED
Floating signal contact |
Signalization designation | DC OK | Status display | LED |
Color | green | DC OK | U |
Number of phases | 3.00 | Insulation voltage input/output | 3 kV AC (type test)
1.5 kV AC (routine test) |
Product type | Power supply | Product family | TRIO POWER |
MTBF (IEC 61709, SN 29500) | > 1800000 h (25 °C)
> 1100000 h (40 °C)
> 510000 h (60 °C) | Article revision | 04 |
Protection class | I (in closed control cabinet) | Degree of pollution | 2 |
Width | 65 mm | Height | 130 mm |
Depth | 160 mm | Installation distance right/left | 0 mm / 0 mm |
Installation distance top/bottom | 50 mm / 50 mm | Mounting type | DIN rail mounting |
Assembly note | alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm | Mounting position | horizontal DIN rail NS 35, EN 60715 |
With protective coating | no | Flammability rating according to UL 94 (housing / terminal blocks) | V0 |
Housing material | Metal | Type of housing | Aluminum (AlMg3) |
Hood version | Polycarbonate | Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) | Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Ambient temperature (start-up type tested) | -40 °C | Maximum altitude | ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m) |
Climatic class | 3K3 (in acc. with EN 60721) | Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) | Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 4g, 90 min. |
Rail applications | EN 50121-4 | Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 | Standard - Electrical safety | IEC 62368-1 (SELV) |
Standard – Safety extra-low voltage | IEC 62368-1 (SELV) und EN 60204-1 (PELV) | Standard - Safe isolation | DIN VDE 0100-410 |
Standard - Safety of transformers | EN 61558-2-16 (air clearances and creepage distances only) | Shipbuilding approval | GL applied for |
UL approvals | UL Listed UL 508
UL/C-UL Recognized UL 60950-1 | SIL in accordance with IEC 61508 | 0 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU | Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
EMC requirements for noise emission | EN 61000-6-3
EN 61000-6-4 | EMC requirements for noise immunity | EN 61000-6-1
EN 61000-6-2 |
Conducted noise emission | EN 55016
EN 61000-6-3 (Class B) | Noise emission | EN 55011 (EN 55022) |
Noise emission | EN 55016
EN 61000-6-3 (Class B) | Frequency range | Class A, B |
Frequency range | 0 kHz ... 2 kHz | Standards/regulations | EN 61000-4-2 |
Contact discharge | 6 kV (Test Level 4) | Discharge in air | 8 kV (Test Level 4) |
Comments | Criterion A | Standards/regulations | EN 61000-4-3 |
Frequency range | 80 MHz ... 6 GHz | Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A | Standards/regulations | EN 61000-4-4 |
Input | 4 kV (Test Level 4 - asymmetrical) | Output | 2 kV (Test Level 3 - asymmetrical) |
Signal | 1 kV (Test Level 2 - asymmetrical) | Comments | Criterion A |
Standards/regulations | EN 61000-4-5 | Input | 1 kV (Test Level 1 - symmetrical)
2 kV (Test Level 1 - asymmetrical) |
Output | 0.5 kV (Test Level 1 - symmetrical)
0.5 kV (Test Level 1 - asymmetrical) | Signal | 1 kV (Test Level 2 - asymmetrical) |
Comments | Criterion B | Standards/regulations | EN 61000-4-6 |
Input/Output | asymmetrical | Frequency range | 0.15 MHz ... 80 MHz |
Comments | Criterion A | Voltage | 10 V (Test Level 3) |
Standards/regulations | EN 61000-4-11 | Voltage | 230 V AC |
Frequency | 50 Hz | Voltage dip | 70 % |
Number of periods | 25 periods | Additional text | Test Level 2 |
Comments | Criterion A | Voltage dip | 40 % |
Number of periods | 10 periods | Additional text | Test Level 2 |
Comments | Criterion A | Voltage dip | 0 % |
Number of periods | 1 period | Additional text | Test Level 2 |
Comments | Criterion A | Standards/regulations | EN 61000-6-3 |
Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential | Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Criterion A | Normal operating behavior within the specified limits. | Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Specifications may be subject to change without notice