Product Model
TRIO-UPS-2G/1AC/1AC/230V/750VA

Selling Points
- 1Space-saving design: UPS module and energy storage combined in one housing.
- 2Smooth transition: Pure sine curve ensures seamless transition to battery operation.
- 3Long buffer times: Integrated VRLA energy storage provides extended backup.
- 4USB interface: Connect to higher-level controllers like industrial PCs safely.
- 5Startup without mains: Possible startup from energy storage even without mains input.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Note on the battery | This product contains a battery with a limited shelf life that must be charged every few months. The product packaging indicates when the battery must be started up or recharged. The general shelf life can be found in the energy storage devices area under “Latest startup”. | Input voltage | 230 V AC |
Input voltage range | 184 V AC ... 264 V AC | Voltage type of supply voltage | AC |
Frequency range (f | 45 Hz ... 55 Hz
55 Hz ... 65 Hz | Current consumption | 3 A (max.) |
Power factor (cos phi) | 0.8 | Input fuse | 10 A 400 V gRL |
Permissible backup fuse | B6 B10 B16 | Designation | Remote |
Low signal | Connection to SGnd with < 2.7 kΩ | High signal | Open (> 35 kΩ between Remote and SGnd) |
Battery-operated start 230 V AC low signal | Connection to SGnd with < 2.7 kΩ | Battery-operated start 230 V AC high signal | Open (> 200 kΩ between Bat.-Start and SGnd) |
Classification according to IEC 62040-3 | VFD-SS-311 | Efficiency | > 95 % (100% load, with charged battery)
~ 81 % (100 % load ) |
Nominal output voltage | 230 V AC | Form of output voltage | Pure sine |
Nominal output current (I | 3 A | Bridging time | 60 s |
UPS connection in parallel | no | UPS connection in series | no |
Apparent power | 750 VA | Nominal power | 600 W (Real power) |
Crest factor | 2.8 | Switch-over time | < 10 ms |
Connection in parallel | no | Connection in series | no |
Nominal output voltage | 230 V AC | Nominal output current (I | 3 A (750 VA) |
Nominal output voltage | 230 V AC | Nominal output current (I | 3 A (750 VA) |
Frequency (after automatic detection in mains operation) | 50 Hz
60 Hz | Output voltage | 24 V (SELV) |
Continuous load current | ≤ 20 mA | Output voltage | 24 V (SELV) |
Continuous load current | ≤ 20 mA | Output voltage | 24 V (SELV) |
Continuous load current | ≤ 20 mA | Signal ground SGnd | Reference potential for Bat.-Mode, Ready, Remote, and Bat.-Start |
Nominal voltage U | 24 V DC | Charging current | 0.7 A ... 1.1 A |
Nominal capacity | 4 Ah | Nominal capacity range | 4 Ah |
Charging time | 7 h | Buffer period | 20 min (100 W)
4 min (300 W)
1 min (600 W) |
Latest startup date (battery only) | 6 Months (0 °C ... 20 °C) | Latest startup (battery only) - range | 6 Months ... 3 Months (20 °C ... 30 °C)
3 Months ... 1 Months (30 °C ... 40 °C) |
Battery technology | Lead rechargeable battery module | Memory medium | Lead rechargeable battery module |
Accumulator type | 2x Panasonic UP-VW1220P1 / BB Battery HR4.2-12FR | Can be extended with external battery | 1x 24 V 4 Ah |
Battery fuse | 40 A, 32 V | Connection method | Push-in connection |
Conductor cross section, rigid min. | 0.2 mm² | Conductor cross section, rigid max. | 4 mm² |
Conductor cross section flexible min. | 0.2 mm² | Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 | Conductor cross section AWG max. | 12 |
Stripping length | 10 mm | Connection method | Push-in connection |
Conductor cross section, rigid min. | 0.2 mm² | Conductor cross section, rigid max. | 4 mm² |
Conductor cross section flexible min. | 0.2 mm² | Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 | Conductor cross section AWG max. | 12 |
Stripping length | 10 mm | Connection method | Push-in connection |
Conductor cross section, rigid min. | 0.2 mm² | Conductor cross section, rigid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² | Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 | Conductor cross section AWG max. | 16 |
Stripping length | 8 mm | Connection method | Push-in connection |
Conductor cross section, rigid min. | 0.2 mm² | Conductor cross section, rigid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² | Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 | Conductor cross section AWG max. | 16 |
Stripping length | 8 mm | Interface | MINI-USB type B |
Maximum cable length | 3 m | Types of signaling | LED |
Signalization designation | Alarm | Status display | LED |
Color | red | Signalization designation | Battery mode |
Status display | LED | Color | yellow |
Signalization designation | Ready | Status display | LED |
Color | green | Signalization designation | Battery charge |
Status display | LED | Color | yellow |
Signalization designation | Service | Status display | LED |
Color | red | Number of phases | 1.00 |
Product type | AC UPS | Product family | TRIO AC UPS – UPS with integrated battery |
MTBF (IEC 61709, SN 29500) | > 206000 h (40 °C) | Article revision | 06 |
Protection class | I | Overvoltage category | III |
Degree of pollution | 2 | Time | 32000 h |
Width | 210 mm | Height | 170 mm |
Depth | 136 mm | Installation distance right/left | 0 mm / 0 mm |
Installation distance top/bottom | 50 mm / 50 mm | Mounting type | DIN rail mounting |
Type of housing | DX51D+AZ (steel sheet / Galvalume) | Hood version | PC + ABS |
Degree of protection | IP20 | Ambient temperature (operation) | 0 °C ... 40 °C |
Ambient temperature (storage/transport) | -15 °C ... 40 °C (with charged energy storage device) | Maximum altitude | ≤ 3000 m (> 2000 m, observe derating) |
Climatic class | 3K3 (in acc. with EN 60721) | Max. permissible relative humidity (operation) | ≤ 95 % (25 °C, non-condensing) |
Shock | 20g in all directions (EN 60068-2-27)
30g in each space direction with UWA 130 | Vibration (operation) | 5 Hz ... 100 Hz, 0.7g (EN 60068-2-6) |
Standard uninterruptible power supply systems | EN 62040-1 | Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC | Interference emission | Noise emission in accordance with EN 62040-2 |
Noise immunity | Immunity in accordance with EN 62040-2 | Conducted noise emission | EN 62040-02 (Class C2) |
Standards/regulations | EN 61000-4-2 | Contact discharge | 6 kV (Test Level 3) |
Discharge in air | 8 kV (Test Level 3) | Comments | Criterion A |
Standards/regulations | EN 61000-4-3 | Frequency range | 80 MHz ... 3 GHz |
Test field strength | 10 V/m | Comments | Criterion A |
Standards/regulations | EN 61000-4-4 | Input | 2 kV (Test Level 3 - asymmetrical)
2 kV (Test Level 3 - asymmetrical) |
Output | 2 kV (Test Level 3 - asymmetrical) | Signal | 2 kV (Test Level 3 - asymmetrical)
2 kV (Test Level 3 - asymmetrical) |
Comments | Criterion A (B for USB) | Standards/regulations | EN 61000-4-5 |
Input | 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical) | Output | 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical) |
Signal | 1 kV (Test Level 2 - asymmetrical) | Comments | Criterion B |
Standards/regulations | EN 61000-4-6 | Frequency range | 0.15 MHz ... 80 MHz |
Comments | Criterion A | Voltage | 10 V |
Standards/regulations | EN 61000-4-8 | Frequency | 50 Hz |
Test field strength | 100 A/m | Comments | Criterion A |
Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential | Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Specifications may be subject to change without notice