Phoenix Contact UK 16 N

Selling Points

  • 1High Voltage Capability: Handles up to 800V nominal voltage.
  • 2High Current Handling: Supports up to 76A nominal current.
  • 3Durable Construction: Made with PA insulating material and rated for V0 flammability.
  • 4Versatile Connectivity: Features screw connection method for easy installation.
  • 5Comprehensive Testing: Meets IEC 60529:2001-02 shock protection standards and passes various tests including surge voltage and power-frequency withstand voltage tests.
Product Details
UK 16 N
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Feed-through terminal block
Product family
UK
Number of connections
2
Number of rows
1
Potentials
1
Article revision
14
Overvoltage category
III
Degree of pollution
3
Rated surge voltage
8 kV
Maximum power dissipation for nominal condition
2.43 W
Number of connections per level
2
Nominal cross section
16 mm²
Screw thread
M4
Tightening torque
1.5 ... 1.8 Nm
Stripping length
11 mm
Internal cylindrical gage
B7
Connection in acc. with standard
IEC 60947-7-1
Conductor cross section rigid
2.5 mm² ... 25 mm²
Cross section AWG
12 ... 4 (converted acc. to IEC)
Conductor cross section flexible
4 mm² ... 16 mm²
Conductor cross section, flexible [AWG]
10 ... 6 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
1.5 mm² ... 16 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
1.5 mm² ... 16 mm²
Cross-section with insertion bridge, rigid
16 mm²
Cross-section with insertion bridge, flexible
16 mm²
2 conductors with same cross section, solid
1.5 mm² ... 6 mm²
2 conductors with same cross section, flexible
1.5 mm² ... 4 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve
1.5 mm² ... 6 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve
0.75 mm² ... 10 mm²
Nominal current
76 A
Maximum load current
101 A (with 25 mm² conductor cross section)
Nominal voltage
800 V
Nominal cross section
16 mm²
Identification
 II 2 GD  Ex eb IIC Gb
Operating temperature range
-60 °C ... 110 °C
Ex-certified accessories
3006027 D-UK 16 1205066 SZS 1,0X4,0 VDE 1201442 E/UK
List of bridges
Fixed bridge / FBI 2-12 / 0200075 Fixed bridge / FBI 10-12 / 0203454
Bridge data
66 A / 16 mm²
Ex temperature increase
40 K (75.1 A / 16 mm²)
Rated voltage
690 V
for bridging with bridge
690 V
Rated insulation voltage
630 V
output
(Permanent)
Rated current
68 A
Maximum load current
91 A
Contact resistance
0.17 mΩ
Torque range
1.5 Nm ... 1.8 Nm
Nominal cross section
16 mm²
Rated cross section AWG
6
Connection capacity rigid
2.5 mm² ... 25 mm²
Connection capacity AWG
14 ... 4
Connection capacity flexible
4 mm² ... 16 mm²
Connection capacity AWG
12 ... 6
2 conductors with same cross section, solid
1.5 mm² ... 6 mm²
2 conductors with the same cross-section AWG rigid
16 ... 10
2 conductors with same cross section, stranded
1.5 mm² ... 4 mm²
2 conductors with the same cross-section AWG flexible
16 ... 12
Width
12.2 mm
End cover width
1.5 mm
Height
42.5 mm
Depth on NS 32
59 mm
Depth on NS 35/7,5
54 mm
Depth on NS 35/15
61.5 mm
Color
gray (RAL 7042)
Flammability rating according to UL 94
V0
Insulating material group
I
Insulating material
PA
Static insulating material application in cold
-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
130 °C
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)
28 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Test voltage setpoint
9.8 kV
Result
Test passed
Requirement temperature-rise test
Increase in temperature ≤ 45 K
Result
Test passed
Short-time withstand current 16 mm²
1.92 kA
Short-time withstand current 25 mm²
3 kA
Result
Test passed
Test voltage setpoint
2 kV
Result
Test passed
Open side panel
Yes
Result
Test passed
DIN rail/fixing support
NS 32/NS 35
Test force setpoint
10 N
Result
Test passed
Rotation speed
10 rpm
Revolutions
135
Conductor cross section/weight
2.5 mm² / 0.7 kg 16 mm² / 2.9 kg 25 mm² / 4.5 kg
Result
Test passed
Time of exposure
30 s
Result
Test passed
Specification
DIN EN 50155 (VDE 0115-200):2008-03
Spectrum
Service life test category 1, class B, body mounted
Frequency
f
ASD level
1.857 (m/s²)²/Hz
Acceleration
0.8g
Test duration per axis
5 h
Test directions
X-, Y- and Z-axis
Result
Test passed
Specification
DIN EN 50155 (VDE 0115-200):2008-03
Pulse shape
Half-sine
Acceleration
5g
Shock duration
30 ms
Number of shocks per direction
3
Test directions
X-, Y- and Z-axis (pos. and neg.)
Result
Test passed
Ambient temperature (operation)
-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Permissible humidity (operation)
20 % ... 90 %
Permissible humidity (storage/transport)
30 % ... 70 %
Connection in acc. with standard
IEC 60947-7-1
Mounting type
NS 35/7,5 NS 35/15 NS 32

Specifications may be subject to change without notice