Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | Feed-through terminal block | Number of positions | 1 |
Number of connections | 2 | Number of rows | 1 |
Article revision | 09 | Overvoltage category | III |
Degree of pollution | 3 | Rated surge voltage | 8 kV |
Maximum power dissipation for nominal condition | 0 W | Number of connections per level | 2 |
Screw thread | M3 | Tightening torque | 0.6 ... 0.8 Nm |
Stripping length | 8 mm | Internal cylindrical gage | A4 |
Connection in acc. with standard | IEC 60947-7-1 | Conductor cross section rigid | 0.2 mm² ... 6 mm² |
Cross section AWG | 24 ... 10 (converted acc. to IEC) | Conductor cross section flexible | 0.2 mm² ... 4 mm² |
Conductor cross section, flexible [AWG] | 24 ... 12 (converted acc. to IEC) | Conductor cross-section flexible (ferrule without plastic sleeve) | 0.25 mm² ... 4 mm² |
Flexible conductor cross section (ferrule with plastic sleeve) | 0.25 mm² ... 2.5 mm² | Cross-section with insertion bridge, rigid | 4 mm² |
Cross-section with insertion bridge, flexible | 4 mm² | 2 conductors with same cross section, solid | 0.2 mm² ... 1.5 mm² |
2 conductors with same cross section, flexible | 0.2 mm² ... 1.5 mm² | 2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² |
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² ... 2.5 mm² | Nominal current | 32 A |
Maximum load current | 41 A (with 6 mm² conductor cross section) | Nominal voltage | 800 V |
Identification | II 2 GD Ex eb IIC Gb | Operating temperature range | -60 °C ... 110 °C |
Ex-certified accessories | 3003020 D-UK 4/10
3006027 D-UK 16
3003224 ATP-UK
1212587 SF-SL 0,6X3,5-100 S-VDE
1201442 E/UK | List of bridges | Fixed bridge / FB 2- 6-EX / 0201456
Fixed bridge / FB 3- 6-EX / 0201469
Fixed bridge / FB 10- 6-EX / 0201281 |
Bridge data | 27.5 A / 4 mm² | List of bridges | Fixed bridge / FBI 10- 6-EX / 0203519 |
Bridge data | 28.5 A / 4 mm² | List of bridges | Chain bridge / KB- 6-EX / 0201485 |
Bridge data | 28 A / 4 mm² | List of bridges | Chain bridge / KBI- 6-EX / 0711849 |
Bridge data | 28 A / 4 mm² | List of bridges | Cross connection bar / FB-150 METER / 0201595
Cross connection bar / ZSR-EX / 0200017 |
Bridge data | 26 A / 4 mm² | Ex temperature increase | 40 K (30 A / 4 mm²) |
Rated voltage | 690 V (NS 35) | for bridging with bridge | 550 V (NS 32) |
- At bridging between non-adjacent terminal blocks | 176 V | Rated insulation voltage | 630 V (NS 35)
500 V (NS 32) |
output | (Permanent) | Rated current | 27 A |
Maximum load current | 35 A | Contact resistance | 0.37 mΩ |
Torque range | 0.6 Nm ... 0.8 Nm | Nominal cross section | 4 mm² |
Rated cross section AWG | 12 | Connection capacity rigid | 0.2 mm² ... 6 mm² |
Connection capacity AWG | 24 ... 10 | Connection capacity flexible | 0.2 mm² ... 4 mm² |
Connection capacity AWG | 24 ... 12 | 2 conductors with same cross section, solid | 0.2 mm² ... 1.5 mm² |
2 conductors with the same cross-section AWG rigid | 24 ... 16 | 2 conductors with same cross section, stranded | 0.2 mm² ... 1.5 mm² |
2 conductors with the same cross-section AWG flexible | 24 ... 16 | Width | 6.2 mm |
End cover width | 1.8 mm | Height | 42.5 mm |
Depth on NS 32 | 52 mm | Depth on NS 35/7,5 | 47 mm |
Depth on NS 35/15 | 54.5 mm | Color | beige (RAL 7032) |
Flammability rating according to UL 94 | V0 | Insulating material group | I |
Insulating material | PA | Static insulating material application in cold | -60 °C |
Relative insulation material temperature index (Elec., UL 746 B) | 130 °C | Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 | Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 | Surface flammability NFPA 130 (ASTM E 162) | passed |
Specific optical density of smoke NFPA 130 (ASTM E 662) | passed | Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
Test voltage setpoint | 8 kV | Result | Test passed |
Requirement temperature-rise test | Increase in temperature ≤ 45 K | Result | Test passed |
Short-time withstand current 4 mm² | 0.48 kA | Short-time withstand current 6 mm² | 0.72 kA |
Result | Test passed | Test voltage setpoint | 2 kV |
Result | Test passed | Open side panel | Yes |
Result | Test passed | DIN rail/fixing support | NS 32/NS 35 |
Test force setpoint | 1 N | Result | Test passed |
Rotation speed | 10 rpm | Revolutions | 135 |
Conductor cross section/weight | 0.2 mm² / 0.2 kg
4 mm² / 0.9 kg
6 mm² / 1.4 kg | Result | Test passed |
Time of exposure | 30 s | Result | Test passed |
Specification | DIN EN 50155 (VDE 0115-200):2018-05 | Spectrum | Service life test category 1, class B, body mounted |
ASD level | 1.857 (m/s²)²/Hz | Acceleration | 0.8g |
Test duration per axis | 5 h | Test directions | X-, Y- and Z-axis |
Result | Test passed | Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
Pulse shape | Half-sine | Acceleration | 5g (10-150-10 Hz) |
Shock duration | 30 ms | Number of shocks per direction | 3 |
Test directions | X-, Y- and Z-axis (pos. and neg.) | Result | Test passed |
Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) | Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
Ambient temperature (assembly) | -5 °C ... 70 °C | Ambient temperature (actuation) | -5 °C ... 70 °C |
Permissible humidity (operation) | 20 % ... 90 % | Permissible humidity (storage/transport) | 30 % ... 70 % |
Connection in acc. with standard | IEC 60947-7-1 | Mounting type | NS 35/7,5
NS 35/15
NS 32 |
Specifications may be subject to change without notice