Selling Points
- 1High-Voltage Rating: Supports up to 800V for robust industrial connections.
- 2High-Current Capacity: Handles a maximum current of 41A, ensuring reliable power transmission.
- 3Screw Connection: Easy and secure connection method using M4 screws.
- 4Non-Grounded Design: Prevents electrical shock with a non-grounded terminal block.
- 5Durable Construction: Built with high-quality materials for long-lasting performance in harsh environments.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | Feed-through terminal block | Number of positions | 1 |
Number of connections | 2 | Number of rows | 1 |
Article revision | 11 | Overvoltage category | III |
Degree of pollution | 3 | Rated surge voltage | 8 kV |
Maximum power dissipation for nominal condition | 1.31 W | Number of connections per level | 2 |
Nominal cross section | 6 mm² | Screw thread | M4 |
Tightening torque | 1.5 ... 1.8 Nm | Stripping length | 10 mm |
Internal cylindrical gage | A5 | Connection in acc. with standard | IEC 60947-7-1 |
Conductor cross section rigid | 0.2 mm² ... 10 mm² | Cross section AWG | 24 ... 8 (converted acc. to IEC) |
Conductor cross section flexible | 0.2 mm² ... 6 mm² | Conductor cross section, flexible [AWG] | 24 ... 10 (converted acc. to IEC) |
Conductor cross-section flexible (ferrule without plastic sleeve) | 0.25 mm² ... 6 mm² | Flexible conductor cross section (ferrule with plastic sleeve) | 0.25 mm² ... 6 mm² |
Cross-section with insertion bridge, rigid | 4 mm² | Cross-section with insertion bridge, flexible | 4 mm² |
2 conductors with same cross section, solid | 0.2 mm² ... 2.5 mm² | 2 conductors with same cross section, flexible | 0.2 mm² ... 2.5 mm² |
2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² | 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² ... 4 mm² |
Nominal current | 41 A | Maximum load current | 57 A (with 10 mm² conductor cross section) |
Nominal voltage | 800 V | Nominal cross section | 6 mm² |
Identification | II 2 GD Ex eb IIC Gb | Operating temperature range | -60 °C ... 110 °C |
Ex-certified accessories | 3003020 D-UK 4/10
3006027 D-UK 16
3003224 ATP-UK
1205066 SZS 1,0X4,0 VDE
1201442 E/UK | List of bridges | Fixed bridge / FB 2- 8-EX / 3029224
Fixed bridge / FB 10- 8-EX / 3003185 |
Bridge data | 37.5 A / 6 mm² | List of bridges | Fixed bridge / FBI 10- 8-EX / 0711700 |
Bridge data | 39.5 A / 6 mm² | Ex temperature increase | 40 K (47 A / 6 mm²) |
Rated voltage | 690 V | for bridging with bridge | 690 V |
Rated insulation voltage | 630 V | output | (Permanent) |
Rated current | 41 A | Maximum load current | 51 A |
Contact resistance | 0.16 mΩ | Torque range | 1.5 Nm ... 1.8 Nm |
Nominal cross section | 6 mm² | Rated cross section AWG | 10 |
Connection capacity rigid | 0.2 mm² ... 10 mm² | Connection capacity AWG | 24 ... 8 |
Connection capacity flexible | 0.2 mm² ... 6 mm² | Connection capacity AWG | 24 ... 10 |
2 conductors with same cross section, solid | 0.2 mm² ... 1.5 mm² | 2 conductors with the same cross-section AWG rigid | 24 ... 16 |
2 conductors with same cross section, stranded | 0.2 mm² ... 1.5 mm² | 2 conductors with the same cross-section AWG flexible | 24 ... 16 |
Width | 8.2 mm | End cover width | 1.8 mm |
Height | 42.5 mm | Depth on NS 32 | 52 mm |
Depth on NS 35/7,5 | 47 mm | Depth on NS 35/15 | 54.5 mm |
Color | black (RAL 9005) | Flammability rating according to UL 94 | V0 |
Insulating material group | I | Insulating material | PA |
Static insulating material application in cold | -60 °C | Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
Relative insulation material temperature index (Elec., UL 746 B) | 130 °C | Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 | Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 | Calorimetric heat release NFPA 130 (ASTM E 1354) | 28 MJ/kg |
Surface flammability NFPA 130 (ASTM E 162) | passed | Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
Smoke gas toxicity NFPA 130 (SMP 800C) | passed | Test voltage setpoint | 9.8 kV |
Result | Test passed | Requirement temperature-rise test | Increase in temperature ≤ 45 K |
Result | Test passed | Short-time withstand current 6 mm² | 0.72 kA |
Result | Test passed | Open side panel | Yes |
Result | Test passed | DIN rail/fixing support | NS 32/NS 35 |
Test force setpoint | 5 N | Result | Test passed |
Time of exposure | 30 s | Result | Test passed |
Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) | Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
Ambient temperature (assembly) | -5 °C ... 70 °C | Ambient temperature (actuation) | -5 °C ... 70 °C |
Permissible humidity (operation) | 20 % ... 90 % | Permissible humidity (storage/transport) | 30 % ... 70 % |
Connection in acc. with standard | IEC 60947-7-1 | Mounting type | NS 35/7,5
NS 35/15 |
Specifications may be subject to change without notice