Phoenix Contact UT 10

Selling Points

  • 1High Surge Voltage Protection: Rated for 8 kV surge voltage, ensuring reliable operation in demanding environments.
  • 2Flexible Conductor Support: Connects solid and stranded conductors without ferrules, accommodating a wide range of conductor cross sections.
  • 3Robust Mechanical Design: Withstand short-time withstand currents up to 1.2 kA and maintain mechanical strength under various conditions.
  • 4Fire Protection Compliance: Meets DIN EN 45545-2 standards for fire protection in rail vehicles, ensuring safety in critical applications.
  • 5Versatile Application: Suitable for process industry, machine building, and plant engineering, offering a versatile solution for various industrial needs.
Product Details
UT 10
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Feed-through terminal block
Product family
UT
Area of application
Railway industry Machine building Plant engineering Process industry
Number of connections
2
Number of rows
1
Potentials
1
Article revision
13
Overvoltage category
III
Degree of pollution
3
Rated surge voltage
8 kV
Maximum power dissipation for nominal condition
1.82 W
Number of connections per level
2
Nominal cross section
10 mm²
Screw thread
M4
Tightening torque
1.5 ... 1.8 Nm
Stripping length
10 mm
Internal cylindrical gage
A6
Connection in acc. with standard
IEC 60947-7-1
Conductor cross section rigid
0.5 mm² ... 16 mm²
Cross section AWG
20 ... 6 (converted acc. to IEC)
Conductor cross section flexible
0.5 mm² ... 16 mm²
Conductor cross section, flexible [AWG]
20 ... 6 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.5 mm² ... 10 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.5 mm² ... 10 mm²
2 conductors with same cross section, solid
0.5 mm² ... 4 mm²
2 conductors with same cross section, flexible
0.5 mm² ... 4 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve
0.5 mm² ... 2.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve
0.5 mm² ... 6 mm²
Nominal current
57 A
Maximum load current
76 A (with 16 mm² conductor cross section)
Nominal voltage
1000 V
Note
Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
Nominal cross section
10 mm²
Identification
 II 2 GD  Ex eb IIC Gb
Operating temperature range
-60 °C ... 110 °C
Ex-certified accessories
3047028 D-UT 2,5/10 1205066 SZS 1,0X4,0 VDE 3022276 CLIPFIX 35-5 3022218 CLIPFIX 35
List of bridges
Plug-in bridge / FBS 2-10 / 3005947 Plug-in bridge / FBS 5-10 / 3005948
Bridge data
54 A / 10 mm²
Ex temperature increase
40 K (60.1 A / 10 mm²)
Rated voltage
690 V
for bridging with bridge
690 V
Rated insulation voltage
630 V
output
(Permanent)
Rated current
54 A
Maximum load current
69 A
Contact resistance
0.16 mΩ
Torque range
1.5 Nm ... 1.8 Nm
Nominal cross section
10 mm²
Rated cross section AWG
8
Connection capacity rigid
0.5 mm² ... 16 mm²
Connection capacity AWG
20 ... 6
Connection capacity flexible
0.5 mm² ... 10 mm²
Connection capacity AWG
20 ... 8
2 conductors with same cross section, solid
0.5 mm² ... 4 mm²
2 conductors with the same cross-section AWG rigid
20 ... 12
2 conductors with same cross section, stranded
0.5 mm² ... 4 mm²
2 conductors with the same cross-section AWG flexible
20 ... 12
Width
10.2 mm
End cover width
2.2 mm
Height
47.7 mm
Depth
46.9 mm
Depth on NS 35/7,5
47.5 mm
Depth on NS 35/15
55 mm
Color
gray (RAL 7042)
Flammability rating according to UL 94
V0
Insulating material group
I
Insulating material
PA
Static insulating material application in cold
-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
125 °C
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)
27,5 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Result
Test passed
Requirement temperature-rise test
Increase in temperature ≤ 45 K
Result
Test passed
Short-time withstand current 10 mm²
1.2 kA
Result
Test passed
Result
Test passed
Open side panel
Yes
Result
Test passed
DIN rail/fixing support
NS 35
Test force setpoint
5 N
Result
Test passed
Rotation speed
10 rpm
Revolutions
135
Conductor cross section/weight
0.5 mm² / 0.3 kg 10 mm² / 2 kg 16 mm² / 2.9 kg
Result
Test passed
Time of exposure
30 s
Result
Test passed
Specification
DIN EN 50155 (VDE 0115-200):2018-05
Spectrum
Service life test category 2, bogie-mounted
Frequency
f
ASD level
6.12 (m/s²)²/Hz
Acceleration
3.12g
Test duration per axis
5 h
Test directions
X-, Y- and Z-axis
Specification
DIN EN 50155 (VDE 0115-200):2008-03
Pulse shape
Half-sine
Acceleration
30g
Shock duration
18 ms
Number of shocks per direction
3
Test directions
X-, Y- and Z-axis (pos. and neg.)
Result
Test passed
Ambient temperature (operation)
-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Permissible humidity (operation)
20 % ... 90 %
Permissible humidity (storage/transport)
30 % ... 70 %
Connection in acc. with standard
IEC 60947-7-1
Mounting type
NS 35/7,5 NS 35/15

Specifications may be subject to change without notice