Phoenix Contact UT 2,5-3L BK

Selling Points

  • 1Compact three-level design for high wiring density.
  • 2Screw connection method for secure and easy installation.
  • 3Supports large-surface labeling for clear overview.
  • 4Tested for railway applications with high reliability.
  • 5Rated for 500V and 19A with flexible conductor cross sections.
Product Details
UT 2,5-3L BK
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Multi-level terminal block
Number of positions
1
Number of connections
6
Number of rows
3
Potentials
3
Article revision
04
Overvoltage category
III
Degree of pollution
3
Rated surge voltage
6 kV
Maximum power dissipation for nominal condition
0.77 W
Number of connections per level
2
Nominal cross section
2.5 mm²
Rated cross section AWG
12
Screw thread
M3
Tightening torque
0.5 ... 0.6 Nm
Stripping length
9 mm
Internal cylindrical gage
A3
Connection in acc. with standard
IEC 60947-7-1
Conductor cross section rigid
0.14 mm² ... 4 mm²
Cross section AWG
26 ... 12 (converted acc. to IEC)
Conductor cross section flexible
0.14 mm² ... 4 mm²
Conductor cross section, flexible [AWG]
26 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.14 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.14 mm² ... 2.5 mm²
2 conductors with same cross section, solid
0.14 mm² ... 1.5 mm²
2 conductors with same cross section, flexible
0.14 mm² ... 1.5 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve
0.14 mm² ... 1.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve
0.5 mm² ... 1.5 mm²
Nominal current
19 A (with a 2.5 mm² conductor cross section)
Maximum load current
24 A (in case of a 4 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors.)
Nominal voltage
500 V
Note
Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
Nominal cross section
2.5 mm²
Connection in acc. with standard
IEC/EN 60079-7
Conductor cross section rigid
0.14 mm² ... 4 mm²
Cross section AWG
26 ... 12 (converted acc. to IEC)
Conductor cross section flexible
0.14 mm² ... 2.5 mm²
Maximum load current
28 A (with 4 mm² conductor cross section) 22 A (with a 2.5 mm² conductor cross section)
Nominal voltage
690 V
Nominal cross section
4 mm²
Width
5.2 mm
End cover width
2.2 mm
Height
90 mm
Depth on NS 35/7,5
77.5 mm
Depth on NS 35/15
85 mm
Color
black (RAL 9005)
Flammability rating according to UL 94
V0
Insulating material group
I
Insulating material
PA
Static insulating material application in cold
-60 °C
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Open side panel
Yes
Ambient temperature (operation)
-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Permissible humidity (operation)
20 % ... 90 %
Permissible humidity (storage/transport)
30 % ... 70 %
Connection in acc. with standard
IEC 60947-7-1 IEC/EN 60079-7
Mounting type
NS 35/7,5 NS 35/15

Specifications may be subject to change without notice