Phoenix Contact UT 4-HESILED 24-P/P-EX

Selling Points

  • 1Compact Design: The UT 4-HESILED 24-P/P-EX features a compact design with dimensions of 6.2 mm width, 57.8 mm length, and 73 mm depth on NS 35/7,5.
  • 2High Surge Voltage: Rated for a surge voltage of 4 kV, ensuring reliable protection against electrical surges.
  • 3LED Indication: Equipped with an LED for 24 V DC, providing visual indication of circuit status.
  • 4Flexible Conductor Options: Supports conductor cross sections from 0.14 mm² to 6 mm², including solid and stranded conductors.
  • 5Durable Insulation: Made with PA insulation material, meeting flammability class UL 94 V0 and insulating material group I.
Product Details
UT 4-HESILED 24-P/P-EX
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Fuse terminal block
Number of positions
1
Number of connections
2
Number of rows
1
Potentials
1
Article revision
02
Overvoltage category
III
Degree of pollution
3
Fuse type
Glass / ceramics / ...
Rated surge voltage
4 kV
Maximum power dissipation for nominal condition
1.02 W
Fuse
G / 5 x 20
LED voltage range
12 V AC/DC ... 30 V AC/DC
Current LED
6.3 A
Maximum current with single arrangement
6.3 A
LED current range
0.31 mA ... 0.95 mA
Maximum power dissipation
max. 1.6 W (with single arrangement of the fuse terminal block in the event of overload) max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload) max. 4 W (with single arrangement of the fuse terminal block in the event of a short-circuit) max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit)
LED voltage range
12 V AC/DC ... 30 V AC/DC
Number of connections per level
2
Nominal cross section
4 mm²
Screw thread
M3
Tightening torque
0.6 ... 0.8 Nm
Stripping length
9 mm
Internal cylindrical gage
A4
Conductor cross section rigid
0.14 mm² ... 6 mm²
Cross section AWG
26 ... 10 (converted acc. to IEC)
Conductor cross section flexible
0.14 mm² ... 6 mm²
Conductor cross section, flexible [AWG]
26 ... 10 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.14 mm² ... 4 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.14 mm² ... 4 mm²
2 conductors with same cross section, solid
0.14 mm² ... 1.5 mm²
2 conductors with same cross section, flexible
0.14 mm² ... 1.5 mm²
Nominal cross section
4 mm²
Identification
 II 3 G  Ex ec llC Gc
Operating temperature range
-60 °C ... 130 °C
Ex-certified accessories
1205053 SZS 0,6X3,5 3022276 CLIPFIX 35-5 3022218 CLIPFIX 35
Rated voltage
275 V
Rated insulation voltage
250 V
output
(Permanent)
Rated current
6.3 A (4 mm²)
Maximum load current
6.3 A (6 mm²)
Contact resistance
5 mΩ
Torque range
0.6 Nm ... 0.8 Nm
Nominal cross section
4 mm²
Rated cross section AWG
12
Connection capacity rigid
0.14 mm² ... 6 mm²
Connection capacity AWG
26 ... 10
Connection capacity flexible
0.14 mm² ... 6 mm²
Connection capacity AWG
26 ... 10
2 conductors with same cross section, solid
0.14 mm² ... 1.5 mm²
2 conductors with the same cross-section AWG rigid
26 ... 16
2 conductors with same cross section, stranded
0.14 mm² ... 1.5 mm²
2 conductors with the same cross-section AWG flexible
26 ... 16
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.14 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
4 mm²
Single conductor/terminal point, flexible, with ferrule, without plastic sleeve, AWG
26 ... 12
Color
black (RAL 9005)
Flammability rating according to UL 94
V0
Insulating material group
I
Insulating material
PA
Open side panel
No
Ambient temperature (operation)
-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Permissible humidity (operation)
20 % ... 90 %
Permissible humidity (storage/transport)
30 % ... 70 %
Mounting type
NS 35/7,5 NS 35/15

Specifications may be subject to change without notice