Phoenix Contact UT 4-PE/HESILED 60 (5X20)

Selling Points

  • 1Versatile Circuit Protection: Designed to protect circuits with glass fuses, ensuring reliable operation and safety.
  • 2LED Indication: Includes an LED indicator for voltage selection, providing clear visual feedback.
  • 3Screw Connection: Features screw connections for easy and secure terminal block arrangement.
  • 4Durable Construction: Built with PA insulating material and rated for high surge voltage (4 kV), ensuring durability.
  • 5Compliant with Standards: Meets IEC 60947-7-2/IEC 60947-7-3 standards for secure and efficient connections.
Product Details
UT 4-PE/HESILED 60 (5X20)
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
General
The current is determined by the fuse used, the voltage by the selected LED.
Product type
Ground terminal block
Number of connections
2
Number of rows
1
Article revision
10
Overvoltage category
III
Degree of pollution
3
Fuse type
Glass / ceramics / ...
Rated surge voltage
4 kV
Maximum power dissipation for nominal condition
1.02 W
Fuse
G / 5 x 20
LED voltage range
30 V AC/DC ... 60 V AC/DC
LED current range
0.4 mA ... 0.86 mA
Maximum power dissipation
max. 1.6 W (with single arrangement of the fuse terminal block in the event of overload) max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload) max. 4 W (with single arrangement of the fuse terminal block in the event of a short-circuit) max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit)
LED voltage range
30 V AC/DC ... 60 V AC/DC
Grounding foot
Yes
Number of connections per level
2
Nominal cross section
4 mm²
Screw thread
M3
Note
Please observe the current carrying capacity of the DIN rails.
Tightening torque
0.6 ... 0.8 Nm
Stripping length
9 mm
Internal cylindrical gage
A4
Connection in acc. with standard
IEC 60947-7-2/IEC 60947-7-3
Conductor cross section rigid
0.14 mm² ... 6 mm²
Cross section AWG
26 ... 10 (converted acc. to IEC)
Conductor cross section flexible
0.5 mm² ... 6 mm²
Conductor cross section, flexible [AWG]
20 ... 10 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.14 mm² ... 4 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.14 mm² ... 4 mm²
Nominal current
6.3 A
Maximum load current
6.3 A (the current is determined by the fuse used)
Nominal voltage
60 V
Nominal cross section
1 mm²
Identification
 II 3 G  Ex ec llC Gc
Operating temperature range
-60 °C ... 130 °C
Ex-certified accessories
1205053 SZS 0,6X3,5 3022276 CLIPFIX 35-5 3022218 CLIPFIX 35
Rated voltage
250 V
output
(Permanent)
Torque range
0.6 Nm ... 0.8 Nm
Nominal cross section
4 mm²
Rated cross section AWG
12
Connection capacity rigid
0.14 mm² ... 6 mm²
Connection capacity AWG
26 ... 10
Connection capacity flexible
0.14 mm² ... 6 mm²
Connection capacity AWG
26 ... 10
2 conductors with same cross section, solid
0.14 mm² ... 1.5 mm²
2 conductors with the same cross-section AWG rigid
26 ... 16
2 conductors with same cross section, stranded
0.14 mm² ... 1.5 mm²
2 conductors with the same cross-section AWG flexible
26 ... 16
Conductor cross section flexible, with ferrule without plastic sleeve min.
0.14 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.
4 mm²
Single conductor/terminal point, flexible, with ferrule, without plastic sleeve, AWG
26 ... 12
output
(Permanent)
Rated current
6.3 A (4 mm²)
Maximum load current
6.3 A (6 mm²)
Contact resistance
5 mΩ
Width
6.2 mm
Height
70.8 mm
Depth on NS 35/7,5
73 mm
Depth on NS 35/15
80.5 mm
Color
black (RAL 9005)
Flammability rating according to UL 94
V0
Insulating material group
I
Insulating material
PA
Static insulating material application in cold
-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
130 °C
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)
28 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Open side panel
No
Ambient temperature (operation)
-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Permissible humidity (operation)
20 % ... 90 %
Permissible humidity (storage/transport)
30 % ... 70 %
Connection in acc. with standard
IEC 60947-7-2/IEC 60947-7-3
Mounting type
NS 35/7,5 NS 35/15

Specifications may be subject to change without notice