  • 1High-current feed-through design with 32A nominal current.
  • 2Compatible with 500V nominal voltage.
  • 3Features a 4mm² nominal cross-section for robust connections.
  • 4Designed for safe and efficient wiring in various applications.
  • 5Easy to install with clear identification of termination points.
Product Details
UT 4-QUATTRO/ 2P
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
General
The max. load current must not be exceeded by the total current of all connected conductors.
Note
The max. load current must not be exceeded by the total current of all connected conductors. With a free-hanging connection, an insulating foil has to be placed between the plug connection and electrically conductive surfaces.
Product type
Plug-in terminal block
Product family
UT
Number of connections
4
Number of rows
1
Potentials
1
Article revision
06
Overvoltage category
III
Degree of pollution
3
Rated surge voltage
6 kV
Maximum power dissipation for nominal condition
1.02 W
Number of connections per level
4
Nominal cross section
4 mm²
Screw thread
M3
Tightening torque
0.6 ... 0.8 Nm
Stripping length
9 mm
Internal cylindrical gage
A4
Connection in acc. with standard
IEC 61984
Conductor cross section rigid
0.14 mm² ... 6 mm²
Cross section AWG
26 ... 10 (converted acc. to IEC)
Conductor cross section flexible
0.14 mm² ... 6 mm²
Conductor cross section, flexible [AWG]
26 ... 10 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.14 mm² ... 4 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.14 mm² ... 4 mm²
2 conductors with same cross section, solid
0.14 mm² ... 1.5 mm²
2 conductors with same cross section, flexible
0.14 mm² ... 1.5 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve
0.14 mm² ... 1.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve
0.5 mm² ... 1 mm²
Nominal current
32 A (observe derating)
Maximum load current
32 A (with 6 mm² conductor cross section)
Nominal voltage
500 V
Nominal cross section
4 mm²
Width
6.2 mm
End cover width
2.2 mm
Height
82.4 mm
Depth on NS 35/7,5
47.5 mm
Depth on NS 35/15
55 mm
Color
gray (RAL 7042)
Flammability rating according to UL 94
V0
Insulating material group
I
Insulating material
PA
Static insulating material application in cold
-60 °C
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Test voltage setpoint
7.3 kV
Result
Test passed
Short-time withstand current 4 mm²
0.48 kA
Result
Test passed
Test voltage setpoint
1.89 kV
Result
Test passed
Open side panel
Yes
Test force setpoint
1 N
Result
Test passed
Insertion/withdrawal cycles
100
Time of exposure
30 s
Result
Test passed
Specification
DIN EN 50155 (VDE 0115-200):2022-06
Spectrum
Service life test category 1, class B, body mounted
Frequency
f
ASD level
0.964 (m/s²)²/Hz
Acceleration
0.58g
Test duration per axis
5 h
Test directions
X-, Y- and Z-axis
Result
Test passed
Specification
DIN EN 50155 (VDE 0115-200):2022-06
Pulse shape
Half-sine
Acceleration
5g
Shock duration
30 ms
Number of shocks per direction
3
Test directions
X-, Y- and Z-axis (pos. and neg.)
Result
Test passed
Ambient temperature (operation)
-60 °C (max. operating temperature see derating curve)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Permissible humidity (operation)
20 % ... 90 %
Permissible humidity (storage/transport)
30 % ... 70 %
Connection in acc. with standard
IEC 61984
Mounting type
NS 35/7,5 NS 35/15