Selling Points
- 1Highly Reliable: Meets stringent standards for railway and industrial applications.
- 2Versatile Connectivity: Supports 2 connections with a cross-section of 0.2 mm² to 10 mm².
- 3Durable Design: Constructed with PA insulating material and a V0 flammability rating.
- 4Easy Installation: Push-in connection method simplifies terminal block installation.
- 5Comprehensive Testing: Passed shock and vibration tests according to DIN EN 50155.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
General | Current and voltage are determined by the plug used. | Note | In plugged-in condition, the most unfavorable paths of the entire plug-in connection are decisive. |
Product type | Ground terminal block | Number of connections | 2 |
Number of rows | 1 | Article revision | 03 |
Overvoltage category | III | Degree of pollution | 3 |
Rated surge voltage | 8 kV | Maximum power dissipation for nominal condition | 1.31 W |
Grounding foot | Yes | Number of connections per level | 2 |
Nominal cross section | 6 mm² | Rated cross section AWG | 8 |
Screw thread | M4 | Note | Please observe the current carrying capacity of the DIN rails. |
Tightening torque | 1.5 ... 1.8 Nm | Stripping length | 10 mm |
Internal cylindrical gage | A5 | Connection in acc. with standard | IEC 61984 |
Conductor cross section rigid | 0.2 mm² ... 10 mm² | Cross section AWG | 24 ... 8 (converted acc. to IEC) |
Conductor cross section flexible | 0.2 mm² ... 10 mm² | Conductor cross section, flexible [AWG] | 24 ... 8 (converted acc. to IEC) |
Conductor cross-section flexible (ferrule without plastic sleeve) | 0.25 mm² ... 6 mm² | Flexible conductor cross section (ferrule with plastic sleeve) | 0.25 mm² ... 6 mm² |
Width | 8.2 mm | End cover width | 2.2 mm |
Height | 49.1 mm | Depth on NS 35/7,5 | 47.5 mm |
Depth on NS 35/15 | 55 mm | Color | green-yellow |
Flammability rating according to UL 94 | V0 | Insulating material group | I |
Insulating material | PA | Static insulating material application in cold | -60 °C |
Relative insulation material temperature index (Elec., UL 746 B) | 130 °C | Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 | Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 | Surface flammability NFPA 130 (ASTM E 162) | passed |
Specific optical density of smoke NFPA 130 (ASTM E 662) | passed | Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
Open side panel | Yes | Specification | DIN EN 50155 (VDE 0115-200):2022-06 |
Spectrum | Service life test category 1, class B, body mounted | Frequency | f |
ASD level | 0.964 (m/s²)²/Hz | Acceleration | 0.58g |
Test duration per axis | 5 h | Test directions | X-, Y- and Z-axis |
Specification | DIN EN 50155 (VDE 0115-200):2022-06 | Pulse shape | Half-sine |
Acceleration | 5g | Shock duration | 30 ms |
Number of shocks per direction | 3 | Test directions | X-, Y- and Z-axis (pos. and neg.) |
Ambient temperature (operation) | -60 °C (max. operating temperature see derating curve) | Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
Ambient temperature (assembly) | -5 °C ... 70 °C | Ambient temperature (actuation) | -5 °C ... 70 °C |
Permissible humidity (operation) | 20 % ... 90 % | Permissible humidity (storage/transport) | 30 % ... 70 % |
Connection in acc. with standard | IEC 61984 | Mounting type | NS 35/7,5
NS 35/15 |
Specifications may be subject to change without notice