UT 6-HESILED 60 (6,3X32)
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
General
The current is determined by the fuse used, the voltage by the selected LED.
Product type
Fuse terminal block
Area of application
Railway industry Machine building Plant engineering
Number of connections
2
Number of rows
1
Potentials
1
Article revision
11
Overvoltage category
III
Degree of pollution
3
Fuse type
Glass / ceramics / ...
Rated surge voltage
6 kV
Maximum power dissipation for nominal condition
1.31 W
Fuse
G / 6,3 x 32
LED voltage range
30 V AC/DC ... 60 V AC/DC
Maximum current with single arrangement
10 A
LED current range
0.4 mA ... 0.86 mA
Maximum power dissipation
max. 1.6 W (with single arrangement of the fuse terminal block in the event of overload) max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload) max. 4 W (with single arrangement of the fuse terminal block in the event of a short-circuit) max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit)
LED voltage range
30 V AC/DC ... 60 V AC/DC
Number of connections per level
2
Nominal cross section
6 mm²
Screw thread
M4
Tightening torque
1.5 ... 1.8 Nm
Stripping length
10 mm
Internal cylindrical gage
A5
Connection in acc. with standard
IEC 60947-7-3
Conductor cross section rigid
0.2 mm² ... 10 mm²
Cross section AWG
24 ... 8 (converted acc. to IEC)
Conductor cross section flexible
0.2 mm² ... 10 mm²
Conductor cross section, flexible [AWG]
24 ... 8 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.25 mm² ... 6 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.25 mm² ... 6 mm²
2 conductors with same cross section, solid
0.2 mm² ... 2.5 mm²
2 conductors with same cross section, flexible
0.2 mm² ... 2.5 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve
0.25 mm² ... 1.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve
0.5 mm² ... 4 mm²
Nominal current
10 A
Maximum load current
10 A (the current is determined by the fuse used)
Nominal voltage
60 V
Nominal cross section
6 mm²
Width
8.2 mm
Height
57.8 mm
Depth on NS 35/7,5
75.6 mm
Depth on NS 35/15
83.1 mm
Color
black (RAL 9005)
Flammability rating according to UL 94
V0
Insulating material group
I
Insulating material
PA
Static insulating material application in cold
-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
125 °C
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)
27,5 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Open side panel
No
Ambient temperature (operation)
-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Permissible humidity (operation)
20 % ... 90 %
Permissible humidity (storage/transport)
30 % ... 70 %
Connection in acc. with standard
IEC 60947-7-3
Mounting type
NS 35/7,5 NS 35/15

Specifications may be subject to change without notice