Product Model
UTI 6-L/L

Selling Points
- 1High current capacity with 38 A nominal current and 47 A maximum load current.
- 2Low-profile design suitable for wiring in flat installation distributors.
- 3Meets DIN EN 45545-2 fire protection standards for rail vehicles.
- 4Gray color with screw connection and rated cross section of 6 mm².
- 5Compatible with NS 35/7,5 and NS 35/15 mounting types.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Product type | Installation terminal block | Number of positions | 2 |
Number of connections | 4 | Number of rows | 3 |
Potentials | 2 | Article revision | 02 |
Overvoltage category | III | Degree of pollution | 3 |
Rated surge voltage | 6 kV | Maximum power dissipation for nominal condition | 1.31 W |
Number of connections per level | 2 | Nominal cross section | 6 mm² |
Screw thread | M3 | Note | Please observe the current carrying capacity of the DIN rails. |
Tightening torque | 0.5 ... 0.6 Nm | Stripping length | 8 mm ... 10 mm |
Internal cylindrical gage | A5
B4 | Conductor cross section rigid | 0.2 mm² ... 10 mm² |
Cross section AWG | 24 ... 8 (converted acc. to IEC) | Conductor cross section flexible | 0.2 mm² ... 10 mm² |
Conductor cross section, flexible [AWG] | 24 ... 8 (converted acc. to IEC) | Conductor cross-section flexible (ferrule without plastic sleeve) | 0.5 mm² ... 6 mm² |
Flexible conductor cross section (ferrule with plastic sleeve) | 0.25 mm² ... 4 mm² | 2 conductors with same cross section, solid | 0.2 mm² ... 2.5 mm² |
2 conductors with same cross section, flexible | 0.2 mm² ... 2.5 mm² | 2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² |
Nominal current | 38 A (with 6 mm² conductor cross section) | Maximum load current | 47 A (with 10 mm² conductor cross section) |
Nominal voltage | 400 V | Nominal cross section | 6 mm² |
Width | 8.2 mm | End cover width | 2.2 mm |
Height | 95 mm | Depth on NS 35/7,5 | 51.5 mm |
Depth on NS 35/15 | 59 mm | Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V0 | Insulating material group | I |
Insulating material | PA | Static insulating material application in cold | -60 °C |
Relative insulation material temperature index (Elec., UL 746 B) | 130 °C | Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 | Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 | Surface flammability NFPA 130 (ASTM E 162) | passed |
Specific optical density of smoke NFPA 130 (ASTM E 662) | passed | Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
Result | Test passed | Requirement temperature-rise test | 45 K |
Result | Test passed | Short-time withstand current 6 mm² | 0.72 kA |
Short-time withstand current 10 mm² | 1.2 kA | Result | Test passed |
Test voltage setpoint | 1.89 kV | Result | Test passed |
Open side panel | Yes | Result | Test passed |
DIN rail/fixing support | NS 35 | Result | Test passed |
Rotation speed | 10 rpm | Revolutions | 135 |
Conductor cross section/weight | 0.2 mm² / 0.2 kg
6 mm² / 1.4 kg
10 mm² / 2 kg | Result | Test passed |
Time of exposure | 30 s | Result | Test passed |
Specification | DIN EN 50155 (VDE 0115-200):2008-03 | Spectrum | Service life test category 2, bogie-mounted |
Frequency | f | ASD level | 6.12 (m/s²)²/Hz |
Acceleration | 3.12g | Test duration per axis | 5 h |
Test directions | X-, Y- and Z-axis | Result | Test passed |
Specification | DIN EN 50155 (VDE 0115-200):2008-03 | Pulse shape | Half-sine |
Acceleration | 30g | Shock duration | 18 ms |
Number of shocks per direction | 3 | Test directions | X-, Y- and Z-axis (pos. and neg.) |
Result | Test passed | Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) | Ambient temperature (assembly) | -5 °C ... 70 °C |
Permissible humidity (operation) | 20 % ... 90 % | Permissible humidity (storage/transport) | 30 % ... 70 % |
Mounting type | NS 35/7,5
NS 35/15 |
Specifications may be subject to change without notice