Product Model
UTTB 2,5/2P-PV

Selling Points
- 1Efficient Connection Management: The UTTB 2,5/2P-PV allows for quick distribution tasks with two function shafts per level.
- 2High Amperage Capacity: Handles up to 24 amps, making it suitable for demanding applications.
- 3Compact Design: Measures 5.2 mm in width, ideal for space-constrained environments.
- 4Feed-through Terminal Block: Designed for feed-through connections, enhancing flexibility in wiring configurations.
- 5Durable Construction: Built to withstand various environmental conditions, including those in the railway industry.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
General | Current and voltage are determined by the plug used. | Product type | Plug-in terminal block |
Product family | UTTB | Number of connections | 4 |
Number of rows | 2 | Potentials | 2 |
Article revision | 05 | Overvoltage category | III |
Degree of pollution | 3 | Rated surge voltage | 6 kV |
Maximum power dissipation for nominal condition | 0.77 W | Number of connections per level | 2 |
Nominal cross section | 2.5 mm² | Screw thread | M3 |
Tightening torque | 0.5 ... 0.6 Nm | Stripping length | 9 mm |
Internal cylindrical gage | A3 | Connection in acc. with standard | IEC 61984 |
Conductor cross section rigid | 0.14 mm² ... 4 mm² | Cross section AWG | 26 ... 12 (converted acc. to IEC) |
Conductor cross section flexible | 0.14 mm² ... 4 mm² | Conductor cross section, flexible [AWG] | 26 ... 12 (converted acc. to IEC) |
Conductor cross-section flexible (ferrule without plastic sleeve) | 0.14 mm² ... 2.5 mm² | Flexible conductor cross section (ferrule with plastic sleeve) | 0.14 mm² ... 2.5 mm² |
2 conductors with same cross section, solid | 0.14 mm² ... 1.5 mm² | 2 conductors with same cross section, flexible | 0.14 mm² ... 1.5 mm² |
2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.14 mm² ... 1.5 mm² | 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² ... 1.5 mm² |
Nominal current | 24 A | Maximum load current | 24 A (with 4 mm² conductor cross section) |
Nominal voltage | 500 V | Nominal cross section | 2.5 mm² |
Width | 5.2 mm | End cover width | 2.2 mm |
Height | 69.9 mm | Depth | 64.4 mm |
Depth on NS 35/7,5 | 65 mm | Depth on NS 35/15 | 72.5 mm |
Color | gray (RAL 7042) | Flammability rating according to UL 94 | V0 |
Insulating material group | I | Insulating material | PA |
Static insulating material application in cold | -60 °C | Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 | Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 | Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
Surface flammability NFPA 130 (ASTM E 162) | passed | Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
Smoke gas toxicity NFPA 130 (SMP 800C) | passed | Test voltage setpoint | 7.3 kV |
Result | Test passed | Short-time withstand current 2.5 mm² | 0.3 kA |
Result | Test passed | Test voltage setpoint | 1.89 kV |
Result | Test passed | Open side panel | Yes |
DIN rail/fixing support | NS 35/7,5 | Result | Test passed |
Insertion/withdrawal cycles | 100 | Time of exposure | 30 s |
Result | Test passed | Specification | DIN EN 50155 (VDE 0115-200):2022-06 |
Spectrum | Service life test category 1, class B, body mounted | Frequency | f |
ASD level | 0.964 (m/s²)²/Hz | Acceleration | 0.58g |
Test duration per axis | 5 h | Test directions | X-, Y- and Z-axis |
Result | Test passed | Specification | DIN EN 50155 (VDE 0115-200):2022-06 |
Pulse shape | Half-sine | Acceleration | 5g |
Shock duration | 30 ms | Number of shocks per direction | 3 |
Test directions | X-, Y- and Z-axis (pos. and neg.) | Result | Test passed |
Ambient temperature (operation) | -60 °C (max. operating temperature see derating curve) | Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
Ambient temperature (assembly) | -5 °C ... 70 °C | Ambient temperature (actuation) | -5 °C ... 70 °C |
Permissible humidity (operation) | 20 % ... 90 % | Permissible humidity (storage/transport) | 30 % ... 70 % |
Connection in acc. with standard | IEC 61984 | Mounting type | NS 35/7,5
NS 35/15 |
Specifications may be subject to change without notice