Phoenix Contact UTTB 2,5 WH

Selling Points

  • 1Efficient Connection Management: Quickly implement all potential distribution tasks with two function shafts per level.
  • 2High Current Capacity: Handles up to 28A maximum load current for reliable performance.
  • 3Durable Construction: Tested for railway applications and meets stringent standards for overvoltage and pollution.
  • 4Easy Installation: Compatible with DIN rail mounting types NS 35/7,5 and NS 35/15 for seamless integration.
  • 5Clear Labeling: Supports large-surface labeling for a clear overview of each terminal point.
Product Details
UTTB 2,5 WH
Phoenix Contact

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Product type
Multi-level terminal block
Area of application
Railway industry Machine building Plant engineering Process industry
Number of connections
4
Number of rows
2
Potentials
2
Article revision
08
Overvoltage category
III
Degree of pollution
3
Rated surge voltage
6 kV
Maximum power dissipation for nominal condition
0.77 W
Number of connections per level
2
Nominal cross section
2.5 mm²
Screw thread
M3
Tightening torque
0.5 ... 0.6 Nm
Stripping length
9 mm
Internal cylindrical gage
A3
Connection in acc. with standard
IEC 60947-7-1
Conductor cross section rigid
0.14 mm² ... 4 mm²
Cross section AWG
26 ... 12 (converted acc. to IEC)
Conductor cross section flexible
0.14 mm² ... 4 mm²
Conductor cross section, flexible [AWG]
26 ... 12 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)
0.14 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)
0.14 mm² ... 2.5 mm²
2 conductors with same cross section, solid
0.14 mm² ... 1.5 mm²
2 conductors with same cross section, flexible
0.14 mm² ... 1.5 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve
0.14 mm² ... 1.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve
0.5 mm² ... 1.5 mm²
Nominal current
24 A
Maximum load current
28 A (in case of a 4 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors.)
Nominal voltage
500 V
Nominal cross section
2.5 mm²
Identification
 II 2 GD  Ex eb IIC Gb
Operating temperature range
-60 °C ... 110 °C
Ex-certified accessories
3047293 D-UTTB 2,5/4 3047303 DP-UTTB 2,5/4 3047316 ATP-UTTB 2,5/4 1205053 SZS 0,6X3,5 3022276 CLIPFIX 35-5 3022218 CLIPFIX 35
List of bridges
Plug-in bridge / FBS 2-5 / 3030161 Plug-in bridge / FBS 3-5 / 3030174 Plug-in bridge / FBS 4-5 / 3030187 Plug-in bridge / FBS 5-5 / 3030190 Plug-in bridge / FBS 10-5 / 3030213 Plug-in bridge / FBS 20-5 / 3030226
Bridge data
20 A / 2.5 mm²
Ex temperature increase
40 K (22.5 A / 2.5 mm²)
Rated voltage
352 V
for bridging with bridge
352 V
- At bridging between non-adjacent terminal blocks
352 V
- At bridging between non-adjacent terminal blocks via PE terminal block
275 V
- At cut-to-length bridging with cover
220 V
- At cut-to-length bridging with partition plate
176 V
Rated insulation voltage
320 V
output
(Permanent)
Rated current
20 A
Maximum load current
24 A
Torque range
0.5 Nm ... 0.6 Nm
Nominal cross section
2.5 mm²
Rated cross section AWG
14
Connection capacity rigid
0.14 mm² ... 4 mm²
Connection capacity AWG
26 ... 12
Connection capacity flexible
0.14 mm² ... 2.5 mm²
Connection capacity AWG
26 ... 14
2 conductors with same cross section, solid
0.14 mm² ... 1.5 mm²
2 conductors with the same cross-section AWG rigid
26 ... 16
2 conductors with same cross section, stranded
0.14 mm² ... 1.5 mm²
2 conductors with the same cross-section AWG flexible
26 ... 16
output
(Permanent)
Contact resistance
0.6 mΩ
output
(Permanent)
Contact resistance
0.4 mΩ
Width
5.2 mm
End cover width
2.2 mm
Height
69.9 mm
Depth
64.4 mm
Depth on NS 35/7,5
65 mm
Depth on NS 35/15
72.5 mm
Color
white (RAL 9010)
Flammability rating according to UL 94
V0
Insulating material group
I
Insulating material
PA
Static insulating material application in cold
-60 °C
Relative insulation material temperature index (Elec., UL 746 B)
130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24
HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3
Surface flammability NFPA 130 (ASTM E 162)
passed
Specific optical density of smoke NFPA 130 (ASTM E 662)
passed
Smoke gas toxicity NFPA 130 (SMP 800C)
passed
Open side panel
Yes
Ambient temperature (operation)
-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)
-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Ambient temperature (assembly)
-5 °C ... 70 °C
Ambient temperature (actuation)
-5 °C ... 70 °C
Permissible humidity (operation)
20 % ... 90 %
Permissible humidity (storage/transport)
30 % ... 70 %
Connection in acc. with standard
IEC 60947-7-1
Mounting type
NS 35/7,5 NS 35/15