Product Model
140G-G2C3-C35-UJ

Selling Points
- 11. High Interrupting Ratings: The 140G-G2C3-C35-UJ boasts an interrupting rating of 50kA at 240V and 65kA at 220-230V AC, ensuring reliable protection against short circuits.;
- 22. Global Standards Compliance: This circuit breaker meets global standards including UL, CSA, CCC, and IEC, ensuring it is suitable for worldwide applications.;
- 33. Thermal Magnetic Design: The thermal magnetic design provides both thermal and magnetic trip units, offering robust protection against overcurrent and short circuits.;
- 44. Reverse-Fed Capability: Designed for reverse-fed applications, this circuit breaker can handle up to 690V AC, making it versatile for various industrial setups.;
- 55. Compact and Reliable: With a compact design and a high mechanical life of 25,000 operations, the 140G-G2C3-C35-UJ is both reliable and space-efficient, fitting well into most panel configurations.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | NON_STOCKED | Dimension Length | 8.6 |
Dimension Width | 14.3 | Lead Time | 15 |
Dimension Height | 13.0 | Quick Turnaround | false |
Preferred Availability | false | Repairable | NOT_REPAIRABLE |
Ambient temperature without derating | 104 | Rated uninterrupted current (Iu) | 98% of current rating @ 3000 m (9840 ft) altitude |
Operational voltage (Ue) | 90% of voltage rating @ 3000 m (9840 ft) altitude | Wire temperature rating | Cu 75 °C |
Storage temperature | -40 | Depth | 70 |
Width | 76.2 | Device construction | Built-in device fixed built-in technique |
Height | 130 | Factory option | Under voltage release, 24...30V AC/DC |
Shock | Peak acceleration: 150 m/s2 peak, pulse duration 11 ms | Vibration | 2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G |
Mechanical life operations | 25000 | Weight | 1.2 |
Degree of protection (IP) | IP40 | DIN rail (top hat rail) mounting optional | Yes |
Suitable for DIN rail (top hat rail) mounting | No | Type of electrical connection of main circuit | Screw connection |
Position of connection for main current circuit | Front side | Motor drive optional | Yes |
With switched-off indicator | No | Motor drive integrated | No |
Rated service short-circuit breaking capacity (Ics) | IEC 60947-2: 75% lcu @ 690V AC @ 50/60Hz | Rated ultimate short-circuit breaking capacity (Icu) | IEC 60947-2: 65kA @ 220...230V AC, 50/60 Hz |
Interrupting rating | 50kA @ 240V, 50/60 Hz per NEMA, UL, CSA | Electrical life cycle | 8000 @ 415V AC |
Construction type | T/M-fixed thermal/fixed magnetic TMF | Insulation voltage (Ui) | Rated 800V per IEC |
Watt loss | Thermal magnetic type: 6.0 W | Votlage for reverse-fed circuit breaker, max | 690V AC per IEC |
Frame size | 125 | Magnetic trip current (Im) | 500 |
Thermal trip current (Ir = In (fixed)) | 35 A | Rated impulse withstand voltage (Uimp) | 8 |
Type of control element | Toggle | Rated permanent current Iu | 35 A |
Complete device with protection unit | Yes | Integrated earth fault protection | No |
With integrated under voltage release | Yes | Number of poles | 3 |
Specifications may be subject to change without notice