Rockwell Automation 140G-G2C3-D12-SD

Selling Points

  • 11. High Interrupting Capacity: The 140G-G2C3-D12-SD features an interrupting rating of 50kA at 240V, 50/60 Hz, ensuring reliable protection against high short-circuit currents.;
  • 22. Robust Construction: Built with a thermal/magnetic trip mechanism, this circuit breaker provides reliable protection against both overloads and short circuits, ensuring the safety of your electrical system.;
  • 33. Wide Operating Range: Designed to operate at 90% of its voltage rating at 3000 meters (9840 feet) altitude, this circuit breaker is suitable for various industrial applications that require high altitude operation.;
  • 44. Compact Design: With dimensions of 76.2 mm in width, 70 mm in depth, and 130 mm in height, the 140G-G2C3-D12-SD is a compact solution for your electrical panel needs.;
  • 55. Global Compliance: Approved for global application, this circuit breaker meets standards from UL, CSA, CCC, and IEC, ensuring compliance with international safety regulations.
Product Details
140G-G2C3-D12-SD
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
14.605
Dimension Width
13.081
Lead Time
23
Dimension Height
13.97
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104 °F
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Cu 75 °C
Storage temperature
-40 °F
Depth
70 mm
Width
76.2 mm
Device construction
Built-in device fixed built-in technique
Height
130 mm
Factory option
Shunt-trip, 110...127V AC @ 110...125V DC
Shock
Peak acceleration: 150 m/s2 peak, pulse duration 11 ms
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
25000 /h
Weight
1.236
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
True
Suitable for DIN rail (top hat rail) mounting
False
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
True
With switched-off indicator
False
Motor drive integrated
False
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 75% lcu @ 690V AC @ 50/60Hz
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 65kA @ 220...230V AC, 50/60 Hz
Interrupting rating
50kA @ 240V, 50/60 Hz per NEMA, UL, CSA
Electrical life cycle
8000 @ 415V AC
Thermal trip rating, max
125 A @ ambient temperature 40 °C
Construction type
T/M-fixed thermal/fixed magnetic TMF
Insulation voltage (Ui)
Rated 800V per IEC
Watt loss
Thermal magnetic type: 32.1 W
Votlage for reverse-fed circuit breaker, max
690V AC per IEC
Frame size
125 A
Magnetic trip current (Im)
1250 A
Thermal trip current (Ir = In (fixed))
125 A
Rated impulse withstand voltage (Uimp)
8 kV
Type of control element
Toggle
Rated permanent current Iu
125 A
Complete device with protection unit
True
Integrated earth fault protection
False
With integrated under voltage release
False
Number of poles
3

Specifications may be subject to change without notice