Product Model
140G-G2C3-D12-SD

Selling Points
- 11. High Interrupting Capacity: The 140G-G2C3-D12-SD features an interrupting rating of 50kA at 240V, 50/60 Hz, ensuring reliable protection against high short-circuit currents.;
- 22. Robust Construction: Built with a thermal/magnetic trip mechanism, this circuit breaker provides reliable protection against both overloads and short circuits, ensuring the safety of your electrical system.;
- 33. Wide Operating Range: Designed to operate at 90% of its voltage rating at 3000 meters (9840 feet) altitude, this circuit breaker is suitable for various industrial applications that require high altitude operation.;
- 44. Compact Design: With dimensions of 76.2 mm in width, 70 mm in depth, and 130 mm in height, the 140G-G2C3-D12-SD is a compact solution for your electrical panel needs.;
- 55. Global Compliance: Approved for global application, this circuit breaker meets standards from UL, CSA, CCC, and IEC, ensuring compliance with international safety regulations.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | NON_STOCKED | Dimension Length | 14.605 |
Dimension Width | 13.081 | Lead Time | 23 |
Dimension Height | 13.97 | Quick Turnaround | false |
Preferred Availability | false | Repairable | NOT_REPAIRABLE |
Ambient temperature without derating | 104 °F | Rated uninterrupted current (Iu) | 98% of current rating @ 3000 m (9840 ft) altitude |
Operational voltage (Ue) | 90% of voltage rating @ 3000 m (9840 ft) altitude | Wire temperature rating | Cu 75 °C |
Storage temperature | -40 °F | Depth | 70 mm |
Width | 76.2 mm | Device construction | Built-in device fixed built-in technique |
Height | 130 mm | Factory option | Shunt-trip, 110...127V AC @ 110...125V DC |
Shock | Peak acceleration: 150 m/s2 peak, pulse duration 11 ms | Vibration | 2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G |
Mechanical life operations | 25000 /h | Weight | 1.236 |
Degree of protection (IP) | IP40 | DIN rail (top hat rail) mounting optional | True |
Suitable for DIN rail (top hat rail) mounting | False | Type of electrical connection of main circuit | Screw connection |
Position of connection for main current circuit | Front side | Motor drive optional | True |
With switched-off indicator | False | Motor drive integrated | False |
Rated service short-circuit breaking capacity (Ics) | IEC 60947-2: 75% lcu @ 690V AC @ 50/60Hz | Rated ultimate short-circuit breaking capacity (Icu) | IEC 60947-2: 65kA @ 220...230V AC, 50/60 Hz |
Interrupting rating | 50kA @ 240V, 50/60 Hz per NEMA, UL, CSA | Electrical life cycle | 8000 @ 415V AC |
Thermal trip rating, max | 125 A @ ambient temperature 40 °C | Construction type | T/M-fixed thermal/fixed magnetic TMF |
Insulation voltage (Ui) | Rated 800V per IEC | Watt loss | Thermal magnetic type: 32.1 W |
Votlage for reverse-fed circuit breaker, max | 690V AC per IEC | Frame size | 125 A |
Magnetic trip current (Im) | 1250 A | Thermal trip current (Ir = In (fixed)) | 125 A |
Rated impulse withstand voltage (Uimp) | 8 kV | Type of control element | Toggle |
Rated permanent current Iu | 125 A | Complete device with protection unit | True |
Integrated earth fault protection | False | With integrated under voltage release | False |
Number of poles | 3 |