Rockwell Automation 140G-G3C3-C90-KJ

Selling Points

  • 11. High Interrupting Capacity: The 140G-G3C3-C90-KJ circuit breaker features an interrupting rating of 65 kA, making it suitable for applications requiring high short-circuit breaking capacity.;
  • 22. Robust Construction: Built with a thermal magnetic type construction, this circuit breaker ensures reliable performance even in harsh industrial environments.;
  • 33. Long Electrical Life Cycle: With an electrical life cycle of 8000 operations at 415V AC, the 140G-G3C3-C90-KJ is designed to provide long-lasting service.;
  • 44. High Ambient Temperature Tolerance: The circuit breaker can operate at ambient temperatures up to 104°F without derating, making it suitable for various industrial settings.;
  • 55. Compliance with International Standards: The 140G-G3C3-C90-KJ meets international standards such as IEC 60947-2, ensuring it is compatible with a wide range of industrial applications.
Product Details
140G-G3C3-C90-KJ
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
11.049
Dimension Width
13.843
Lead Time
15
Dimension Height
11.049
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Cu 75 °C
Storage temperature
-40
Depth
70
Width
76.2
Device construction
Built-in device fixed built-in technique
Height
130
Factory option
1 NO/NC auxiliary, 24V AC/DC
Shock
Peak acceleration: 150 m/s2 peak, pulse duration 11 ms
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
25000
Weight
1.211
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
Yes
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
Yes
With switched-off indicator
No
Motor drive integrated
No
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 75% lcu @ 220...230V AC @ 50/60Hz
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 85kA @ 220...230V AC, 50/60 Hz
Interrupting rating
65kA @ 240V, 50/60 Hz per NEMA, UL, CSA
Electrical life cycle
8000 @ 415V AC
Thermal trip rating, max
90 A @ ambient temperature 40 °C
Construction type
T/M-fixed thermal/fixed magnetic TMF
Insulation voltage (Ui)
Rated 800V per IEC
Watt loss
Thermal magnetic type: 17.0 W
Votlage for reverse-fed circuit breaker, max
690V AC per IEC
Frame size
125
Magnetic trip current (Im)
900
Thermal trip current (Ir = In (fixed))
90
Rated impulse withstand voltage (Uimp)
8
Type of control element
Toggle
Rated permanent current Iu
90
Complete device with protection unit
Yes
Integrated earth fault protection
No
With integrated under voltage release
No
Number of auxiliary contacts as change-over contact
1
Number of poles
3