Rockwell Automation 140G-G3C3-D10-SJ-AJ

Selling Points

  • 11. High Performance and Reliability: The Allen Bradley 140G-G3C3-D10-SJ-AJ is built to withstand rigorous industrial environments, ensuring long-term performance and minimal downtime. Its thermal magnetic protection guarantees reliable operation under various conditions.;
  • 22. Comprehensive Specifications: This circuit breaker features a 125A frame with a load rating of 100A. It has a breaking capacity of 50kA at 415V, making it suitable for a wide range of industrial applications.;
  • 33. Certified for Safety: The product is certified with various international standards, including IEC and UL, ensuring it meets the highest safety and performance criteria. This certification provides peace of mind for users in diverse global markets.;
  • 44. Versatile Mounting Options: The Allen Bradley 140G-G3C3-D10-SJ-AJ offers flexible mounting options, including front-side screw connections, making it easy to integrate into existing systems. This flexibility enhances its usability in various industrial settings.;
  • 55. Durable Construction: Constructed with high-quality materials, this circuit breaker is designed to withstand harsh environmental conditions. It has an IP40 degree of protection, ensuring it remains functional even in challenging settings.
Product Details
140G-G3C3-D10-SJ-AJ
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
16.891
Dimension Width
12.954
Lead Time
23
Dimension Height
11.557
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104 °F
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Cu 75 °C
Storage temperature
-40 °F
Depth
70 mm
Width
76.2 mm
Device construction
Built-in device fixed built-in technique
Height
130 mm
Factory option
Shunt-trip, 24...30V AC/DC
Shock
Peak acceleration: 150 m/s2 peak, pulse duration 11 ms
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
25000 /h
Weight
1.241
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
True
Suitable for DIN rail (top hat rail) mounting
False
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
True
With switched-off indicator
False
Motor drive integrated
False
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 75% lcu @ 220...230V AC @ 50/60Hz
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 85kA @ 220...230V AC, 50/60 Hz
Interrupting rating
65kA @ 240V, 50/60 Hz per NEMA, UL, CSA
Electrical life cycle
8000 @ 415V AC
Thermal trip rating, max
94 A @ ambient temperature 50 °C
Construction type
T/M-fixed thermal/fixed magnetic TMF
Insulation voltage (Ui)
Rated 800V per IEC
Watt loss
Thermal magnetic type: 21.0 W
Votlage for reverse-fed circuit breaker, max
690V AC per IEC
Frame size
125 A
Magnetic trip current (Im)
1000 A
Thermal trip current (Ir = In (fixed))
100 A
Rated impulse withstand voltage (Uimp)
8 kV
Type of control element
Toggle
Rated permanent current Iu
100 A
Complete device with protection unit
True
Integrated earth fault protection
False
With integrated under voltage release
False
Number of auxiliary contacts as change-over contact
1
Number of poles
3

Specifications may be subject to change without notice