Product Model
140G-G3C3-D12-AJ-MT

Selling Points
- 11. Reliability and Performance: The Allen Bradley 140G-G3C3-D12 is built to withstand rigorous industrial environments, ensuring long-term performance and minimal downtime.;
- 22. High Capacity: With a 125A rating, this circuit breaker is suitable for demanding applications, providing reliable power distribution in high-performance plants.;
- 33. Thermal Magnetic Design: The thermal magnetic design ensures that the breaker operates efficiently under various load conditions, providing consistent performance.;
- 44. Backward Compatibility: Designed with backward compatibility in mind, the Allen Bradley 140G-G3C3-D12 can integrate seamlessly with older systems, extending its useful life.;
- 55. Manufacturer Support: As part of Rockwell Automation, Allen Bradley products benefit from strong aftermarket support, ensuring that procurement professionals can troubleshoot and maintain the equipment effectively.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | NON_STOCKED | Dimension Length | 24.257 |
Dimension Width | 21.844 | Lead Time | 15 |
Dimension Height | 18.796 | Quick Turnaround | false |
Preferred Availability | false | Repairable | NOT_REPAIRABLE |
Ambient temperature without derating | 104 °F | Rated uninterrupted current (Iu) | 98% of current rating @ 3000 m (9840 ft) altitude |
Operational voltage (Ue) | 90% of voltage rating @ 3000 m (9840 ft) altitude | Wire temperature rating | Cu 75 °C |
Storage temperature | -40 °F | Depth | 70 mm |
Width | 76.2 mm | Device construction | Built-in device fixed built-in technique |
Height | 130 mm | Factory option | Standard busbar mount, top ftd |
Shock | Peak acceleration: 150 m/s2 peak, pulse duration 11 ms | Vibration | 2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G |
Mechanical life operations | 25000 /h | Weight | 2.492 |
Degree of protection (IP) | IP40 | DIN rail (top hat rail) mounting optional | True |
Suitable for DIN rail (top hat rail) mounting | False | Type of electrical connection of main circuit | Screw connection |
Position of connection for main current circuit | Front side | Motor drive optional | True |
With switched-off indicator | False | Motor drive integrated | False |
Rated service short-circuit breaking capacity (Ics) | IEC 60947-2: 75% lcu @ 220...230V AC @ 50/60Hz | Rated ultimate short-circuit breaking capacity (Icu) | IEC 60947-2: 85kA @ 220...230V AC, 50/60 Hz |
Interrupting rating | 65kA @ 240V, 50/60 Hz per NEMA, UL, CSA | Electrical life cycle | 8000 @ 415V AC |
Thermal trip rating, max | 125 A @ ambient temperature 40 °C | Construction type | T/M-fixed thermal/fixed magnetic TMF |
Insulation voltage (Ui) | Rated 800V per IEC | Watt loss | Thermal magnetic type: 32.1 W |
Votlage for reverse-fed circuit breaker, max | 690V AC per IEC | Frame size | 125 A |
Magnetic trip current (Im) | 1250 A | Thermal trip current (Ir = In (fixed)) | 125 A |
Rated impulse withstand voltage (Uimp) | 8 kV | Type of control element | Toggle |
Rated permanent current Iu | 125 A | Complete device with protection unit | True |
Integrated earth fault protection | False | With integrated under voltage release | False |
Number of auxiliary contacts as change-over contact | 1 | Number of poles | 3 |
Specifications may be subject to change without notice