Rockwell Automation 140G-G6C3-C16-AJ

Selling Points

  • 11. Reliable Protection: The 140G-G6C3-C16 provides comprehensive thermal/magnetic protection, ensuring that your control panels are safeguarded against electrical faults and overloads.;
  • 22. High Interrupting Capacity: With a 65 kA interrupting capacity at 480V, this circuit breaker is capable of handling high-energy discharges, making it ideal for applications requiring robust line protection.;
  • 33. Compact Design: Designed for space-saving dimensions, the 140G-G6C3-C16 is perfect for installations where real estate is limited, yet reliability is paramount.;
  • 44. Global Compliance: Approved for global applications, this circuit breaker meets stringent standards including UL, CSA, CCC, and IEC performance interrupting/breaking capacity, ensuring compliance in various international markets.;
  • 55. Versatile Mounting Options: Featuring end cap/bolt-on terminals as standard, the 140G-G6C3-C16 offers a wide range of mounting options, allowing for flexible installation in various electrical configurations.
Product Details
140G-G6C3-C16-AJ
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
9.906
Dimension Width
14.732
Lead Time
15
Dimension Height
13.589
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104 °F
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Cu 75 °C
Storage temperature
-40 °F
Depth
70 mm
Width
76.2 mm
Device construction
Built-in device fixed built-in technique
Height
130 mm
Factory option
1 NO/NC auxiliary + 1 alarm 24V AC/DC
Shock
Peak acceleration: 150 m/s2 peak, pulse duration 11 ms
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
25000 /h
Weight
1.211
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
True
Suitable for DIN rail (top hat rail) mounting
False
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
True
With switched-off indicator
False
Motor drive integrated
False
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 75% lcu @ 500V DC, 3-poles in series, thermal-magnetic trip unit only
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 70kA @ 500V DC, 3-poles in series, thermal-magnetic trip unit only
Interrupting rating
65kA @ 480V, 50/60 Hz per NEMA, UL, CSA
Electrical life cycle
8000 @ 415V AC
Thermal trip rating, max
16 A @ ambient temperature 40 °C
Construction type
T/M-fixed thermal/fixed magnetic TMF
Insulation voltage (Ui)
Rated 800V per IEC
Watt loss
Thermal magnetic type: 4.5 W
Votlage for reverse-fed circuit breaker, max
690V AC per IEC
Frame size
125 A
Magnetic trip current (Im)
500 A
Thermal trip current (Ir = In (fixed))
16 A
Rated impulse withstand voltage (Uimp)
8 kV
Type of control element
Toggle
Rated permanent current Iu
16 A
Complete device with protection unit
True
Integrated earth fault protection
False
With integrated under voltage release
False
Number of auxiliary contacts as change-over contact
1
Number of poles
3

Specifications may be subject to change without notice