Product Model
140G-G6C3-C50-SA-BA

Selling Points
- 11. High Current Rating: The 140G-G6C3-C50-SA features a current rating of 125A, making it suitable for high-power applications in industrial settings.;
- 22. Enhanced Safety: With a 70kA IEC breaking capacity, this circuit breaker ensures robust protection against short circuits, ensuring the safety of personnel and equipment.;
- 33. Global Certifications: Certified for various global standards, including IEC 60947-2, this product meets international safety and performance requirements, enhancing its reliability and compatibility.;
- 44. Durable Construction: Constructed with high-quality materials, the 140G-G6C3-C50-SA is designed to withstand rigorous industrial environments, ensuring long-term performance and minimal downtime.;
- 55. Easy Installation: Featuring a straightforward installation process and clear documentation, this circuit breaker simplifies integration into existing control systems, reducing setup time and costs.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Weight Unit | KG | Stock Status | NON_STOCKED |
Dimension Length | 0.0 | Dimension Width | 0.0 |
Lead Time | 23 | Dimension Height | 0.0 |
Quick Turnaround | false | Preferred Availability | false |
Repairable | NOT_REPAIRABLE | Ambient temperature without derating | 104 °F |
Rated uninterrupted current (Iu) | 98% of current rating @ 3000 m (9840 ft) altitude | Operational voltage (Ue) | 90% of voltage rating @ 3000 m (9840 ft) altitude |
Wire temperature rating | Cu 75 °C | Storage temperature | -40 °F |
Depth | 70 mm | Width | 76.2 mm |
Device construction | Built-in device fixed built-in technique | Height | 130 mm |
Factory option | Shunt-trip, 220...240V AC @ 220...250V DC | Shock | Peak acceleration: 150 m/s2 peak, pulse duration 11 ms |
Vibration | 2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G | Mechanical life operations | 25000 /h |
Weight | 0.999 | Degree of protection (IP) | IP40 |
DIN rail (top hat rail) mounting optional | True | Suitable for DIN rail (top hat rail) mounting | False |
Type of electrical connection of main circuit | Screw connection | Position of connection for main current circuit | Front side |
Motor drive optional | True | With switched-off indicator | False |
Motor drive integrated | False | Rated service short-circuit breaking capacity (Ics) | IEC 60947-2: 75% lcu @ 500V DC, 3-poles in series, thermal-magnetic trip unit only |
Rated ultimate short-circuit breaking capacity (Icu) | IEC 60947-2: 70kA @ 500V DC, 3-poles in series, thermal-magnetic trip unit only | Interrupting rating | 65kA @ 480V, 50/60 Hz per NEMA, UL, CSA |
Electrical life cycle | 8000 @ 415V AC | Thermal trip rating, max | 50 A @ ambient temperature 40 °C |
Construction type | T/M-fixed thermal/fixed magnetic TMF | Insulation voltage (Ui) | Rated 800V per IEC |
Watt loss | Thermal magnetic type: 11.1 W | Votlage for reverse-fed circuit breaker, max | 690V AC per IEC |
Frame size | 125 A | Magnetic trip current (Im) | 500 A |
Thermal trip current (Ir = In (fixed)) | 50 A | Rated impulse withstand voltage (Uimp) | 8 kV |
Type of control element | Toggle | Rated permanent current Iu | 50 A |
Complete device with protection unit | True | Integrated earth fault protection | False |
With integrated under voltage release | False | Number of auxiliary contacts as change-over contact | 2 |
Number of poles | 3 |
Specifications may be subject to change without notice