Rockwell Automation 140G-G6C3-C90-SJ-AA

Selling Points

  • 11. High-Quality Construction: Designed to withstand rigorous industrial environments, ensuring long-term performance and minimal downtime.;
  • 22. Advanced Thermal Magnetic Technology: Provides reliable protection against electrical overloads and short circuits.;
  • 33. Versatile Application: Suitable for a wide range of industrial automation applications, including high-voltage systems.;
  • 44. Backward Compatibility: Designed with backward compatibility in mind, ensuring seamless integration with older systems.;
  • 55. Manufacturer Support: Backed by Rockwell Automation's strong aftermarket support, providing confidence in troubleshooting and maintenance.
Product Details
140G-G6C3-C90-SJ-AA
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
0.0
Dimension Width
0.0
Lead Time
23
Dimension Height
0.0
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104 °F
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Cu 75 °C
Storage temperature
-40 °F
Depth
70 mm
Width
76.2 mm
Device construction
Built-in device fixed built-in technique
Height
130 mm
Factory option
Shunt-trip, 24...30V AC/DC
Shock
Peak acceleration: 150 m/s2 peak, pulse duration 11 ms
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
25000 /h
Weight
0.999
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
True
Suitable for DIN rail (top hat rail) mounting
False
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
True
With switched-off indicator
False
Motor drive integrated
False
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 75% lcu @ 500V DC, 3-poles in series, thermal-magnetic trip unit only
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 70kA @ 500V DC, 3-poles in series, thermal-magnetic trip unit only
Interrupting rating
65kA @ 480V, 50/60 Hz per NEMA, UL, CSA
Electrical life cycle
8000 @ 415V AC
Thermal trip rating, max
90 A @ ambient temperature 40 °C
Construction type
T/M-fixed thermal/fixed magnetic TMF
Insulation voltage (Ui)
Rated 800V per IEC
Watt loss
Thermal magnetic type: 17.0 W
Votlage for reverse-fed circuit breaker, max
690V AC per IEC
Frame size
125 A
Magnetic trip current (Im)
900 A
Thermal trip current (Ir = In (fixed))
90 A
Rated impulse withstand voltage (Uimp)
8 kV
Type of control element
Toggle
Rated permanent current Iu
90 A
Complete device with protection unit
True
Integrated earth fault protection
False
With integrated under voltage release
False
Number of auxiliary contacts as change-over contact
1
Number of poles
3

Specifications may be subject to change without notice