  • 11. High Interrupting Capacity: The Allen-Bradley 140G-G6E3-D16-KJ boasts an impressive interrupting capacity of 65 kA at 480V, ensuring reliable protection against high fault currents.;
  • 22. Adjustable Thermal/Magnetic Trip: This circuit breaker features a thermal/magnetic trip unit that can be adjusted to meet specific application needs, providing customizable protection settings.;
  • 33. Global Application Compatibility: Designed for global use, this breaker meets international standards including UL, CSA, CCC, and IEC, ensuring compatibility with various electrical systems worldwide.;
  • 44. Compact Design: The compact design of the 140G-G6E3-D16-KJ makes it suitable for a wide range of panel configurations, minimizing space while maximizing functionality.;
  • 55. Reliable Protection: With its robust construction and high-quality materials, the Allen-Bradley 140G-G6E3-D16-KJ provides reliable protection against overloads, short circuits, and ground faults in industrial electrical systems.
Product Details
140G-G6E3-D16-KJ
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
10.16
Dimension Width
14.478
Lead Time
23
Dimension Height
13.462
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104 °F
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Cu 75 °C
Storage temperature
-40 °F
Depth
70 mm
Width
76.2 mm
Device construction
Built-in device fixed built-in technique
Height
130 mm
Factory option
1 NO/NC auxiliary, 24V AC/DC
Shock
Peak acceleration: 150 m/s2 peak, pulse duration 11 ms
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
25000 /h
Weight
1.204
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
True
Suitable for DIN rail (top hat rail) mounting
False
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
True
With switched-off indicator
False
Motor drive integrated
False
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 75% lcu @ 500V DC, 3-poles in series, thermal-magnetic trip unit only
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 70kA @ 500V DC, 3-poles in series, thermal-magnetic trip unit only
Interrupting rating
65kA @ 480V, 50/60 Hz per NEMA, UL, CSA
Electrical life cycle
8000 @ 415V AC
Thermal trip rating, max
160 A @ ambient temperature 40 °C (IEC only)
Construction type
T/M-Adjustable thermal/fixed magnetic TMD
Insulation voltage (Ui)
Rated 800V per IEC
Watt loss
Thermal magnetic type: 45.0 W
Votlage for reverse-fed circuit breaker, max
690V AC per IEC
Thermal trip current (Ir)
112 A
Frame size
125 A
Magnetic trip current (Im)
1600 A
Rated impulse withstand voltage (Uimp)
8 kV
Type of control element
Toggle
Rated permanent current Iu
160 A
Complete device with protection unit
True
Integrated earth fault protection
False
With integrated under voltage release
False
Number of auxiliary contacts as change-over contact
1
Number of poles
3