Product Model
140G-H0I3-D10-SD-DA

Selling Points
- 11. High Interrupting Rating: The 140G-H0I3-D10-SD-DA boasts a 35kA interrupting rating, ensuring it can handle high short-circuit currents with ease, making it a reliable choice for industrial applications.;
- 22. Electronic Short-Time Trip Units: Equipped with electronic short-time trip units, this circuit breaker provides precise and fast response times to protect against electrical faults, ensuring the safety and efficiency of your operations.;
- 33. Robust Construction: Built with a robust construction, the 140G-H0I3-D10-SD-DA is designed to withstand the rigors of industrial environments, providing long-term performance and minimal downtime.;
- 44. IP40 Protection: Featuring IP40 protection, this circuit breaker is resistant to dust and water ingress, ensuring it operates effectively in a variety of industrial settings.;
- 55. Backward Compatibility: Designed with backward compatibility in mind, the 140G-H0I3-D10-SD-DA can integrate seamlessly with older systems, extending the useful life of your industrial automation equipment.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | NON_STOCKED | Dimension Length | 0.0 |
Dimension Width | 0.0 | Lead Time | 15 |
Dimension Height | 0.0 | Quick Turnaround | false |
Preferred Availability | false | Repairable | NOT_REPAIRABLE |
Ambient temperature without derating | 104 °F | Rated uninterrupted current (Iu) | 98% of current rating @ 3000 m (9840 ft) altitude |
Operational voltage (Ue) | 90% of voltage rating @ 3000 m (9840 ft) altitude | Wire temperature rating | Cu 75 °C |
Storage temperature | -40 °F | Depth | 82.5 mm |
Width | 90 mm | Device construction | Built-in device fixed built-in technique |
Height | 130 mm | Factory option | Shunt-trip, 110...127V AC @ 110...125V DC |
Shock | Peak acceleration: 150 m/s2 peak, pulse duration 11 ms | Vibration | 2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G |
Mechanical life operations | 25000 /h | Weight | 0.999 |
Degree of protection (IP) | IP40 | DIN rail (top hat rail) mounting optional | True |
Suitable for DIN rail (top hat rail) mounting | False | Type of electrical connection of main circuit | Screw connection |
Position of connection for main current circuit | Front side | Motor drive optional | True |
With switched-off indicator | False | Motor drive integrated | False |
Protection type | Electronic LSIG-long and short time, high Instantaneous, ground fault | Rated service short-circuit breaking capacity (Ics) | IEC 60947-2: 100% lcu @ 500V DC, 3-poles in series, thermal-magnetic trip unit only |
Rated ultimate short-circuit breaking capacity (Icu) | IEC 60947-2: 85kA @ 500V DC, 3-poles in series, thermal-magnetic trip unit only | Interrupting rating | 35kA @ 600V AC, 50/60 Hz per NEMA, UL, CSA |
Operating current (In), max | 93A @ 50°C (122 ?F) per UL | Protection typeâElectronic S (short time trip units) | I2 = 1...10 x In (100...1000 A), t2 = 0.05, 0.1, 0.2, 0.4 s |
Protection typeâElectronic G (ground fault trip units) | I4 = 0.2...1 x In (20...100 A), t2 = 0.1, 0.2, 0.4, 0.8 s | Protection typeâElectronic L (long time trip units) | I1 = 0.4...1 x In (40...100 A), t1 = 3, 12, 36, 60 s |
Electrical life cycle | 8000 @ 415V AC | Insulation voltage (Ui) | Rated 1000V per IEC |
Protection typeâElectronic I (instantaneous trip units) | I3 = 1...10 x In (100...1000 A) | Watt loss | Electronic type: 12.6 W |
Voltage for reverse-fed circuit breaker, max | 480V AC per UL/CSA | Frame size | 125 A |
Rated impulse withstand voltage (Uimp) | 8 kV | Type of control element | Toggle |
Rated permanent current Iu | 100 A | Complete device with protection unit | True |
Integrated earth fault protection | True | With integrated under voltage release | False |
Number of poles | 3 |
Specifications may be subject to change without notice