Product Model
140G-H6C3-C15-AJ

Selling Points
- 11. High Interrupting Capacity: The Allen-Bradley 140G-H6C3-C15-AJ boasts an impressive interrupting capacity of 65kA at 480V AC and 70kA at 415V, ensuring it can handle high short-circuit currents effectively.;
- 22. Reliable Motor Protection: This circuit breaker is UL listed, providing 100% breakers that allow the full range of motor protection to be utilized, ensuring the safety and efficiency of your motor systems.;
- 33. Thermal Magnetic Design: The thermal magnetic design offers both thermal and magnetic trip currents, providing comprehensive protection against overloads and short circuits. The thermal trip current is 15A, and the magnetic trip current is 400A.;
- 44. Compact and Durable: With a frame size of 125A, this circuit breaker is compact and designed to be durable, with a mechanical life of 25,000 operations and a weight of 2.65 lbs. It also meets IP40 standards for protection against solid particles.;
- 55. Versatile Installation Options: The Allen-Bradley 140G-H6C3-C15-AJ can be mounted with screw connections on the front side, making it easy to integrate into various industrial settings. It also supports DIN rail mounting as an optional feature.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | NON_STOCKED | Dimension Length | 0.0 |
Dimension Width | 0.0 | Lead Time | 15 |
Dimension Height | 0.0 | Quick Turnaround | false |
Preferred Availability | false | Repairable | NOT_REPAIRABLE |
Ambient temperature without derating | 104 °F | Rated uninterrupted current (Iu) | 98% of current rating @ 3000 m (9840 ft) altitude |
Operational voltage (Ue) | 90% of voltage rating @ 3000 m (9840 ft) altitude | Wire temperature rating | Cu 75 °C |
Storage temperature | -40 °F | Depth | 82.5 mm |
Width | 90 mm | Device construction | Built-in device fixed built-in technique |
Height | 130 mm | Factory option | 1 NO/NC auxiliary + 1 alarm 24V AC/DC |
Shock | Peak acceleration: 150 m/s2 peak, pulse duration 11 ms | Vibration | 2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G |
Mechanical life operations | 25000 /h | Weight | 0.999 |
Degree of protection (IP) | IP40 | DIN rail (top hat rail) mounting optional | True |
Suitable for DIN rail (top hat rail) mounting | False | Type of electrical connection of main circuit | Screw connection |
Position of connection for main current circuit | Front side | Motor drive optional | True |
With switched-off indicator | False | Motor drive integrated | False |
Protection type | T/M-fixed thermal/fixed magnetic TMF | Rated service short-circuit breaking capacity (Ics) | IEC 60947-2: 100% lcu @ 500V DC, 3-poles in series, thermal-magnetic trip unit only |
Rated ultimate short-circuit breaking capacity (Icu) | IEC 60947-2: 70kA @ 500V DC, 3-poles in series, thermal-magnetic trip unit only | Interrupting rating | 65kA @ 480V AC, 50/60 Hz per NEMA, UL, CSA |
Electrical life cycle | 8000 @ 415V AC | Thermal trip rating, max | 15 A @ ambient temperature 40 °C |
Insulation voltage (Ui) | Rated 1000V per IEC | Watt loss | Thermal magnetic type: 3.4 W |
Voltage for reverse-fed circuit breaker, max | 480V AC per UL/CSA | Thermal trip current (Ir) | 15 A |
Magnetic trip current (Im) | 400 A | Frame size | 125 A |
Rated impulse withstand voltage (Uimp) | 8 kV | Type of control element | Toggle |
Rated permanent current Iu | 15 A | Complete device with protection unit | True |
Integrated earth fault protection | False | With integrated under voltage release | False |
Number of auxiliary contacts as change-over contact | 1 | Number of poles | 3 |
Specifications may be subject to change without notice