  • 11. High Interrupting Capacity: The Allen-Bradley 140G-H6C3-C20-AA circuit breaker offers a high interrupting capacity of 25 kA, ensuring reliable protection against short circuits and other electrical faults.;
  • 22. Minimal Mounting Footprint: Designed for compact installations, this circuit breaker minimizes the space required, making it ideal for applications where space is limited.;
  • 33. Versatile Application: Suitable for a wide range of applications, including three-phase power systems, single-phase systems, and DC power systems, this breaker provides flexibility in various industrial settings.;
  • 44. Compliance with Global Standards: The 140G-H6C3-C20-AA complies with UL, CSA, and IEC standards, ensuring it meets the necessary safety and performance requirements for global use.;
  • 55. Reliable Protection: Equipped with thermal-magnetic trip units, this circuit breaker provides reliable protection against overload and short circuits, ensuring the safety of your electrical system.
Product Details
140G-H6C3-C20-AA
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
22.352
Dimension Width
14.986
Lead Time
15
Dimension Height
13.589
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104 °F
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Cu 75 °C
Storage temperature
-40 °F
Depth
82.5 mm
Width
90 mm
Device construction
Built-in device fixed built-in technique
Height
130 mm
Factory option
1 NO/NC auxiliary + 1 alarm, 250V AC/DC
Shock
Peak acceleration: 150 m/s2 peak, pulse duration 11 ms
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
25000 /h
Weight
1.715
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
True
Suitable for DIN rail (top hat rail) mounting
False
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
True
With switched-off indicator
False
Motor drive integrated
False
Protection type
T/M-fixed thermal/fixed magnetic TMF
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 100% lcu @ 500V DC, 3-poles in series, thermal-magnetic trip unit only
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 70kA @ 500V DC, 3-poles in series, thermal-magnetic trip unit only
Interrupting rating
65kA @ 480V AC, 50/60 Hz per NEMA, UL, CSA
Electrical life cycle
8000 @ 415V AC
Thermal trip rating, max
20 A @ ambient temperature 40 °C
Insulation voltage (Ui)
Rated 1000V per IEC
Watt loss
Thermal magnetic type: 4.8 W
Voltage for reverse-fed circuit breaker, max
480V AC per UL/CSA
Thermal trip current (Ir)
20 A
Magnetic trip current (Im)
400 A
Frame size
125 A
Rated impulse withstand voltage (Uimp)
8 kV
Type of control element
Toggle
Rated permanent current Iu
20 A
Complete device with protection unit
True
Integrated earth fault protection
False
With integrated under voltage release
False
Number of auxiliary contacts as change-over contact
1
Number of poles
3