  • 11. High Interrupting Ratings: The Allen-Bradley 140G-H6C3-C70 boasts high interrupting ratings, capable of handling up to 65kA at 480V AC, making it suitable for demanding industrial applications.;
  • 22. Thermal-Magnetic Protection: Equipped with a thermal-magnetic trip unit, this circuit breaker provides robust protection against overloads and short circuits, ensuring the safety of your electrical system.;
  • 33. Compact Design: With a compact design, the 140G-H6C3-C70 fits seamlessly into various panel configurations, minimizing space while maximizing functionality.;
  • 44. IP40 Protection: Featuring IP40 protection, this circuit breaker offers a high level of protection against solid particles and dust, ensuring reliable operation in harsh environments.;
  • 55. Customizable Trip Units: The 140G-H6C3-C70 allows for customizable trip units, enabling you to adjust the current threshold and time response to meet the specific needs of your application, enhancing overall system efficiency and safety.
Product Details
140G-HC6C3-C70
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
0.0
Dimension Width
0.0
Lead Time
13
Dimension Height
0.0
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104 °F
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Cu 75 °C
Storage temperature
-40 °F
Depth
82.5 mm
Width
90 mm
Device construction
Built-in device fixed built-in technique
Frame size
125 A H frame current limiting
Height
130 mm
Factory option
None
Mechanical life operations
25000 /h
Weight
0.999
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
True
Suitable for DIN rail (top hat rail) mounting
False
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
True
With switched-off indicator
False
Motor drive integrated
False
Protection type
T/M-fixed thermal/fixed magnetic TMF
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 100% lcu @ 690V AC @ 50/60Hz
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 70kA @ 500V DC, 2 poles in series
Interrupting rating
65kA @ 480V AC, 50/60 Hz per NEMA, UL, CSA
Interrupting rating (I2t)
655 x 103, rated current (In) upto 125A @ 600V AC
Intermediate point (I2t)
480 x 103, rated current (In) upto 125A @ 480V AC
Threshold current (I2t)
301 x 103, rated current (In) upto 125A @ 600V AC
Threshold current (Ip)
10 kA, rated current (In) upto 125A @ 600V AC
Interrupting rating (Ip)
23.2 kA, rated current (In) upto 125A @ 480V AC
Intermediate point (Ip)
19 kA, rated current (In) upto 125A @ 480V AC
Interrupting rating (Irms)
65 kA, rated current (In) upto 125A @ 480V AC
Threshold current (Irms)
6 kA, rated current (In) upto 125A @ 600V AC
Intermediate point (Irms)
30 kA, rated current (In) upto 125A @ 480V AC
Electrical life cycle
8000 @ 415V AC
Insulation voltage (Ui)
Rated 1000V per IEC
Thermal trip current (Ir)
70 A
Magnetic trip current (Im)
700 A
Rated impulse withstand voltage (Uimp)
8 kV
Type of control element
Toggle
Rated permanent current Iu
70 A
Complete device with protection unit
True
Integrated earth fault protection
False
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70 kA
With integrated under voltage release
False
Number of poles
3

Specifications may be subject to change without notice