Selling Points

  • 11. High Interrupting Ratings: The 140G-HC6H3-D12 boasts an interrupting rating of 65 kA at 480V AC, ensuring it can handle high fault currents effectively, making it suitable for demanding industrial applications.;
  • 22. Electronic Protection: Equipped with electronic protection units, this circuit breaker provides instantaneous and long-time trip capabilities, ensuring reliable protection against overloads and short circuits.;
  • 33. Compact Design: With dimensions of 130 mm H x 90 mm W x 82.5 mm D, the 140G-HC6H3-D12 is designed to be compact and space-efficient, making it easy to integrate into various panel configurations.;
  • 44. Global Certifications: Certified to international standards such as UL, CSA, CCC, and IEC, ensuring compliance with global safety regulations and standards.;
  • 55. Customization Options: Available in various frame sizes and with optional current-limiting features, the 140G-HC6H3-D12 offers greater customization to meet specific application requirements, enhancing its versatility in industrial settings.
Product Details
140G-HC6H3-D12
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
22.352
Dimension Width
15.875
Lead Time
13
Dimension Height
13.462
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104 °F
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Cu 75 °C
Storage temperature
-40 °F
Depth
82.5 mm
Width
90 mm
Device construction
Built-in device fixed built-in technique
Frame size
125 A H frame current limiting
Height
130 mm
Factory option
None
Mechanical life operations
25000 /h
Weight
1.742
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
True
Suitable for DIN rail (top hat rail) mounting
False
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
True
With switched-off indicator
False
Motor drive integrated
False
Protection type
Electronic LSI-long and short time, high instantaneous
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 100% lcu @ 690V AC @ 50/60Hz
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 70kA @ 500V DC, 2 poles in series
Interrupting rating
65kA @ 480V AC, 50/60 Hz per NEMA, UL, CSA
Protection type—Electronic S (short time trip units)
I2 = 1...10 x In (125...1250), t2 = 0.05, 0.1, 0.2, 0.4 s
Interrupting rating (I2t)
655 x 103, rated current (In) upto 125A @ 600V AC
Intermediate point (I2t)
480 x 103, rated current (In) upto 125A @ 480V AC
Threshold current (I2t)
301 x 103, rated current (In) upto 125A @ 600V AC
Threshold current (Ip)
10 kA, rated current (In) upto 125A @ 600V AC
Interrupting rating (Ip)
23.2 kA, rated current (In) upto 125A @ 480V AC
Intermediate point (Ip)
19 kA, rated current (In) upto 125A @ 480V AC
Interrupting rating (Irms)
65 kA, rated current (In) upto 125A @ 480V AC
Threshold current (Irms)
6 kA, rated current (In) upto 125A @ 600V AC
Intermediate point (Irms)
30 kA, rated current (In) upto 125A @ 480V AC
Protection type—Electronic L (long time trip units)
I1 = 0.4...1 x In (50...125), t1 = 3, 12, 36, 60 s
Electrical life cycle
8000 @ 415V AC
Insulation voltage (Ui)
Rated 1000V per IEC
Protection type—Electronic I (instantaneous trip units)
I3 = 1...10 x In (125...1250)
Rated impulse withstand voltage (Uimp)
8 kV
Type of control element
Toggle
Rated permanent current Iu
125 A
Complete device with protection unit
True
Integrated earth fault protection
False
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70 kA
With integrated under voltage release
False
Number of poles
3

Specifications may be subject to change without notice