Rockwell Automation 140G-K6F3-D30-Z1-CA

Selling Points

  • 11. High-Performance Design: The Allen-Bradley 140G-K6F3-D30-Z1 is engineered to withstand the toughest industrial environments, ensuring consistent performance and reliability.;
  • 22. Adjustable Thermal and Magnetic Management: This circuit breaker features adjustable thermal and magnetic management, allowing for precise control over its operation to meet specific application needs.;
  • 33. Long-Term Reliability: Designed to last, the 140G-K6F3-D30-Z1 is built to minimize downtime, reducing the need for frequent replacements and maintenance.;
  • 44. Industrial-Grade Quality: Constructed with high-quality materials, this circuit breaker is ideal for demanding industrial applications where reliability is paramount.;
  • 55. Backward Compatibility: Allen-Bradley products are designed with backward compatibility in mind, ensuring that this circuit breaker can integrate seamlessly with older systems, extending its useful life and value.
Product Details
140G-K6F3-D30-Z1-CA
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
0.0
Dimension Width
0.0
Lead Time
16
Dimension Height
0.0
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Al or Cu 75°C
Storage temperature
-40
Depth
108.5
Width
140
Device construction
Built-in device fixed built-in technique
Height
205
Factory option
3 NO/NC auxiliary + 1 alarm, 250V AC/DC
Shock
Peak acceleration: 150 m/s2 peak, pulse duration 11 ms
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
20000
Weight
0.999
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
Yes
With switched-off indicator
No
Motor drive integrated
No
Protection type
T/M-adjustable thermal/adjustable magnetic TMA
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 100% Icu @ 750V DC, 3-poles in series, thermal-magnetic trip units only
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 70kA @ 400...415V AC, 50/60 Hz
Interrupting rating
65kA @ 480V AC, 50/60 Hz per NEMA, UL, CSA
Electrical life cycle
7000 (400 A)/5000 (600 A) @ 415V AC
Thermal trip rating, max
300 A @ ambient temperature 40 °C
Insulation voltage (Ui)
Rated 1000V per IEC
Watt loss
Thermal magnetic type: 40.8 W
Voltage for reverse-fed circuit breaker, max
690V AC per IEC
Magnetic trip current (Im)
1500
Thermal trip current (Ir)
210
Current range
100% MCCB
Frame size
400
Rated impulse withstand voltage (Uimp)
8
Type of control element
Toggle
Rated permanent current Iu
300
Complete device with protection unit
Yes
Integrated earth fault protection
No
With integrated under voltage release
No
Number of auxiliary contacts as change-over contact
3
Number of poles
3

Specifications may be subject to change without notice