Rockwell Automation 140G-K6F3-D40-Z1-SJ-AA

Selling Points

  • 11. Reliability and Durability: The 140G-K6F3-D40-Z1-SJ-AA circuit breaker is built to withstand rigorous industrial environments, ensuring long-term performance and minimal downtime.;
  • 22. High-Intensity Protection: Equipped with a 65 kA interrupt rating, this breaker provides robust protection against high-intensity electrical surges, safeguarding your equipment and personnel.;
  • 33. Efficient Operation: Designed for thermal magnetic protection, the 140G-K6F3-D40-Z1-SJ-AA ensures efficient operation under various load conditions, maintaining optimal performance.;
  • 44. Versatile Application: Suitable for a wide range of industrial applications, this circuit breaker is a versatile solution for any high-demand environment, from manufacturing plants to power distribution systems.;
  • 55. Backward Compatibility: Allen Bradley’s commitment to backward compatibility ensures that the 140G-K6F3-D40-Z1-SJ-AA can integrate seamlessly with older systems, extending its useful life and maximizing your investment.
Product Details
140G-K6F3-D40-Z1-SJ-AA
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
0.0
Dimension Width
0.0
Lead Time
23
Dimension Height
0.0
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104 °F
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Al or Cu 75°C
Storage temperature
-40 °F
Depth
108.5 mm
Width
140 mm
Device construction
Built-in device fixed built-in technique
Height
205 mm
Factory option
Shunt-trip, 24...30V AC/DC
Shock
Peak acceleration: 150 m/s2 peak, pulse duration 11 ms
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
20000 /h
Weight
0.999
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
False
Suitable for DIN rail (top hat rail) mounting
False
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
True
With switched-off indicator
False
Motor drive integrated
False
Protection type
T/M-adjustable thermal/adjustable magnetic TMA
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 100% Icu @ 750V DC, 3-poles in series, thermal-magnetic trip units only
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 70kA @ 400...415V AC, 50/60 Hz
Interrupting rating
65kA @ 480V AC, 50/60 Hz per NEMA, UL, CSA
Electrical life cycle
7000 (400 A)/5000 (600 A) @ 415V AC
Thermal trip rating, max
400 A @ ambient temperature 40 °C
Insulation voltage (Ui)
Rated 1000V per IEC
Watt loss
Thermal magnetic type: 58.5 W
Voltage for reverse-fed circuit breaker, max
690V AC per IEC
Magnetic trip current (Im)
2000 A
Thermal trip current (Ir)
280 A
Current range
100% MCCB
Frame size
400 A
Rated impulse withstand voltage (Uimp)
8 kV
Type of control element
Toggle
Rated permanent current Iu
400 A
Complete device with protection unit
True
Integrated earth fault protection
False
With integrated under voltage release
False
Number of auxiliary contacts as change-over contact
1
Number of poles
3