  • 11. High Current Capacity: The 140G-K6H3-D40 circuit breaker handles 400A, making it suitable for high-current applications in industrial settings.;
  • 22. Reliability in Demanding Environments: Designed to withstand rigorous industrial conditions, this circuit breaker ensures long-term performance and minimal downtime.;
  • 33. Advanced Protection Features: With 65 kA at 480V, this breaker provides robust protection against electrical surges and faults, ensuring the safety of your equipment and personnel.;
  • 44. Ease of Installation: The 140G-K6H3-D40 is designed for easy installation, reducing setup time and minimizing the need for specialized tools.;
  • 55. Backward Compatibility: Allen Bradley products are known for their backward compatibility, ensuring that this circuit breaker can integrate seamlessly with older systems, extending its useful life and maximizing its value.
Product Details
140G-K6H3-D40-SD-AA
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
0.0
Dimension Width
0.0
Lead Time
16
Dimension Height
0.0
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Al or Cu 75°C
Storage temperature
-40
Depth
108.5
Width
140
Device construction
Built-in device fixed built-in technique
Height
205
Factory option
Shunt-trip, 110...127V AC @ 110...125V DC
Shock
Peak acceleration: 150 m/s2 peak, pulse duration 11 ms
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
20000
Weight
0.999
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
Yes
With switched-off indicator
No
Motor drive integrated
No
Protection type
Electronic LSI-long and short time, high instantaneous
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 100% Icu @ 750V DC, 3-poles in series, thermal-magnetic trip units only
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 70kA @ 400...415V AC, 50/60 Hz
Interrupting rating
65kA @ 480V AC, 50/60 Hz per NEMA, UL, CSA
Operating current (In), max
400A @ 60°C (140 ?F) per IEC
Protection type—Electronic S (short time trip units)
I2 = 1...10 x In (240...4000 A), t2 = 0.05, 0.1, 0.25, 0.5 s
Protection type—Electronic L (long time trip units)
I1 = 0.4...1 x In (160...400 A), t1 = 3, 6, 9, 18 s
Electrical life cycle
7000 (400 A)/5000 (600 A) @ 415V AC
Insulation voltage (Ui)
Rated 1000V per IEC
Protection type—Electronic I (instantaneous trip units)
I3 = 1...10 x In (600...4800 A)
Voltage for reverse-fed circuit breaker, max
690V AC per IEC
Current range
80% MCCB
Frame size
400
Rated impulse withstand voltage (Uimp)
8
Type of control element
Toggle
Rated permanent current Iu
400
Complete device with protection unit
Yes
Integrated earth fault protection
No
With integrated under voltage release
No
Number of auxiliary contacts as change-over contact
1
Number of poles
3

Specifications may be subject to change without notice