Rockwell Automation 140G-KC0F3-D40

Selling Points

  • 11. High Interrupting Capacity: The Allen-Bradley 140G-KC0F3-D40 boasts an impressive interrupting capacity of 65kA at 600V AC, ensuring it can handle high short-circuit currents effectively.;
  • 22. Adjustable Trip Units: Equipped with adjustable thermal and magnetic trip units, this circuit breaker provides customizable protection settings to match your specific application needs.;
  • 33. Reliable Protection: Designed for industrial applications, the 140G-KC0F3-D40 offers robust protection against overloads, short circuits, and ground faults, ensuring the safety of your electrical system.;
  • 44. Versatile Mounting Options: Although not suitable for DIN rail mounting, the circuit breaker’s front-side screw connections provide flexibility in installation, making it easy to integrate into various electrical systems.;
  • 55. Durable Construction: Built with a durable construction and rated for 75°C wire temperature, the 140G-KC0F3-D40 can withstand harsh industrial environments and maintain its performance over time.
Product Details
140G-KC0F3-D40
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
0.0
Dimension Width
0.0
Lead Time
43
Dimension Height
0.0
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104 °F
Rated uninterrupted current (Iu)
98% @ 3000 metre (9840 ft) altitude
Operational voltage (Ue)
90% @ 3000 metre (9840 ft) altitude
Wire temperature rating
Al or Cu 75 °C
Storage temperature
-40 °F
Depth
108.5 mm
Width
140 mm
Device construction
Built-in device fixed built-in technique
Height
205 mm
Factory option
None
Mechanical life operations
240 /h
Weight
0.999
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
True
Suitable for DIN rail (top hat rail) mounting
False
Insulation voltage
Rated 1000V per IEC
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
True
With switched-off indicator
False
Motor drive integrated
False
Protection type
T/M-adjustable thermal/adjustable magnetic TMA
Rated ultimate short-circuit breaking capacity (Icu) per IEC 60947-2 rating
85kA @ 500V AC, 50/60 Hz
Interrupting rating per UL 489/CSA C22.2, No. 5
65kA @ 600V, 50/60 Hz
Rated service short-circuit breaking capacity (Ics(% Icu)) per IEC 60947-2 rating
100% @ 690V AC, 50/60 Hz
Interrupting rating (I2t)
2.8x103 @ rated current up to 400 A, rated voltage 600V AC
Intermediate point (I2t)
2.4x103 @ rated current up to 400 A, rated voltage 480V AC
Threshold current (I2t)
1.5x103 @ rated current up to 400 A, rated voltage 600V AC
Threshold current (Ip)
21 kA @ rated current up to 400 A, rated voltage 600V AC
Interrupting rating (Ip)
43.9 @ rated current up to 400 A, rated voltage 480V AC
Intermediate point (Ip)
35 kA @ rated current up to 400 A, rated voltage 480V AC
Interrupting rating (Irms)
65 kA @ rated current up to 400 A, rated voltage 480V AC
Threshold current (Irms)
10 ka @ rated current up to 400 A, rated voltage 600V AC
Intermediate point (Irms)
30 kA @ rated current up to 400 A, rated voltage 480V AC
Electrical life cycle
7000 (400 A)/5000 (600 A) ops @ 415V AC
Magnetic trip current (Im)
2000 A
Thermal trip current (Ir)
280 A
Frame size
400 A
Rated impulse withstand voltage (Uimp)
8 kV
Type of control element
Toggle
Rated permanent current Iu
400 A
Complete device with protection unit
True
Integrated earth fault protection
False
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
120 kA
With integrated under voltage release
False
Number of poles
3

Specifications may be subject to change without notice