Product Model
140G-KC0H3-D40

Selling Points
- 11. High Interrupt Rating: The 140G-KC0H3-D40 boasts a 100 kA interrupt rating, ensuring reliable operation under high fault currents.;
- 22. Electronic LSI Protection: Equipped with electronic LSI (long and short time) protection, this circuit breaker provides fast and accurate overcurrent detection and response.;
- 33. Versatile Application: Designed for 3-phase power applications, it can handle currents up to 400 A, making it versatile for various industrial settings.;
- 44. Durable Construction: Built with a robust design, the 140G-KC0H3-D40 ensures long-lasting performance and reliability in harsh industrial environments.;
- 55. Easy Installation: Featuring a front-side connection for the main current circuit and screw connections, this circuit breaker is easy to install and integrate into existing systems.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Weight Unit | KG | Stock Status | NON_STOCKED |
Dimension Length | 0.0 | Dimension Width | 0.0 |
Lead Time | 15 | Dimension Height | 0.0 |
Quick Turnaround | false | Preferred Availability | false |
Repairable | NOT_REPAIRABLE | Ambient temperature without derating | 104 °F |
Rated uninterrupted current (Iu) | 98% @ 3000 metre (9840 ft) altitude | Operational voltage (Ue) | 90% @ 3000 metre (9840 ft) altitude |
Wire temperature rating | Al or Cu 75 °C | Storage temperature | -40 °F |
Depth | 108.5 mm | Width | 140 mm |
Device construction | Built-in device fixed built-in technique | Height | 205 mm |
Factory option | None | Mechanical life operations | 240 /h |
Weight | 0.999 | Degree of protection (IP) | IP40 |
DIN rail (top hat rail) mounting optional | True | Suitable for DIN rail (top hat rail) mounting | False |
Insulation voltage | Rated 1000V per IEC | Type of electrical connection of main circuit | Screw connection |
Position of connection for main current circuit | Front side | Motor drive optional | True |
With switched-off indicator | False | Motor drive integrated | False |
Protection type | Electronic LSI-long and short time, high instantaneous | Rated ultimate short-circuit breaking capacity (Icu) per IEC 60947-2 rating | 85kA @ 500V AC, 50/60 Hz |
Interrupting rating per UL 489/CSA C22.2, No. 5 | 65kA @ 600V, 50/60 Hz | Rated service short-circuit breaking capacity (Ics(% Icu)) per IEC 60947-2 rating | 100% @ 690V AC, 50/60 Hz |
Protection typeâElectronic S (short time trip units) | I2 = 1...10 x In (240...4000), t2 = 0.05, 0.1, 0.25, 0.5 s | Interrupting rating (I2t) | 2.8x103 @ rated current up to 400 A, rated voltage 600V AC |
Intermediate point (I2t) | 2.4x103 @ rated current up to 400 A, rated voltage 480V AC | Threshold current (I2t) | 1.5x103 @ rated current up to 400 A, rated voltage 600V AC |
Threshold current (Ip) | 21 kA @ rated current up to 400 A, rated voltage 600V AC | Interrupting rating (Ip) | 43.9 @ rated current up to 400 A, rated voltage 480V AC |
Intermediate point (Ip) | 35 kA @ rated current up to 400 A, rated voltage 480V AC | Interrupting rating (Irms) | 65 kA @ rated current up to 400 A, rated voltage 480V AC |
Threshold current (Irms) | 10 ka @ rated current up to 400 A, rated voltage 600V AC | Intermediate point (Irms) | 30 kA @ rated current up to 400 A, rated voltage 480V AC |
Protection typeâElectronic L (long time trip units) | I1 = 0.4...1 x In (160...400), t1 = 3, 6, 12, 18 s | Electrical life cycle | 7000 (400 A)/5000 (600 A) ops @ 415V AC |
Protection typeâElectronic I (instantaneous trip units) | I3 = 1...10 x In (600...4800) | Frame size | 400 A |
Rated impulse withstand voltage (Uimp) | 8 kV | Type of control element | Toggle |
Rated permanent current Iu | 400 A | Complete device with protection unit | True |
Integrated earth fault protection | False | Rated short-circuit breaking capacity lcu at 400 V, 50 Hz | 120 kA |
With integrated under voltage release | False | Number of poles | 3 |
Specifications may be subject to change without notice