Rockwell Automation 140G-M0F3-D60-CJ

Selling Points

  • 11. Reliable Electrical Protection: The Allen-Bradley 140G-M0F3-D60 is engineered to provide robust electrical protection, ensuring the safety of your equipment and personnel in industrial settings.;
  • 22. Adjustable Trip Settings: With adjustable thermal and magnetic trip settings, this circuit breaker can be tailored to meet specific application requirements, enhancing its versatility and effectiveness.;
  • 33. High-Performance Design: Designed for 800A M Frame configurations, this breaker is built to handle high currents while maintaining efficiency and reliability.;
  • 44. Compliance with IEC Standards: The 140G-M0F3-D60 meets IEC standards for safety and efficiency, providing a reliable solution for applications where compliance is crucial.;
  • 55. Versatile Application: Suitable for a wide range of industrial applications, this circuit breaker offers a flexible solution that can be integrated into various electrical systems, making it an essential component for many industries.
Product Details
140G-M0F3-D60-CJ
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
38.608
Dimension Width
31.496
Lead Time
15
Dimension Height
30.226
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104 °F
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Al or Cu 75 °C
Storage temperature
-40 °F
Depth
103.5 mm
Width
210 mm
Device construction
Built-in device fixed built-in technique
Height
268 mm
Factory option
3 NO/NC auxiliary + 1 alarm, 24V AC/DC
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
20000 /h
Weight
9.852
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
True
Suitable for DIN rail (top hat rail) mounting
False
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
True
With switched-off indicator
False
Motor drive integrated
False
Protection type
T/M-adjustable thermal/adjustable magnetic TMA
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 75% Icu @ 750V DC, 3-poles in series, thermal-magnetic trip units only
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 80kA @ 440V AC, 50/60 Hz
Interrupting rating
50kA @ 600V DC, 3-pole in series, thermal-magnetic trip only per NEMA, UL, CSA
Electrical life cycle
7000 (600...630 A)/5000 (800 A) @ 415V AC
Thermal trip rating, max
600 A @ ambient temperature 40 °C
Insulation voltage (Ui)
Rated 1000V per IEC
Watt loss
Thermal magnetic type: 90 W
Voltage for reverse-fed circuit breaker, max
690V AC per IEC
Magnetic trip current (Im)
3000 A
Thermal trip current (Ir)
420 A
Current range
80% MCCB
Frame size
800 A
Rated impulse withstand voltage (Uimp)
8 kV
Type of control element
Toggle
Rated permanent current Iu
600 A
Complete device with protection unit
True
Integrated earth fault protection
False
With integrated under voltage release
False
Number of auxiliary contacts as change-over contact
3
Number of poles
3

Specifications may be subject to change without notice