- 11. Reliable Electrical Protection: The Allen-Bradley 140G-M0F3-D60 is engineered to provide robust electrical protection, ensuring the safety of your equipment and personnel in industrial settings.;
- 22. Adjustable Trip Settings: With adjustable thermal and magnetic trip settings, this circuit breaker can be tailored to meet specific application requirements, enhancing its versatility and effectiveness.;
- 33. High-Performance Design: Designed for 800A M Frame configurations, this breaker is built to handle high currents while maintaining efficiency and reliability.;
- 44. Compliance with IEC Standards: The 140G-M0F3-D60 meets IEC standards for safety and efficiency, providing a reliable solution for applications where compliance is crucial.;
- 55. Versatile Application: Suitable for a wide range of industrial applications, this circuit breaker offers a flexible solution that can be integrated into various electrical systems, making it an essential component for many industries.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | NON_STOCKED | Dimension Length | 38.608 |
Dimension Width | 31.496 | Lead Time | 15 |
Dimension Height | 30.226 | Quick Turnaround | false |
Preferred Availability | false | Repairable | NOT_REPAIRABLE |
Ambient temperature without derating | 104 °F | Rated uninterrupted current (Iu) | 98% of current rating @ 3000 m (9840 ft) altitude |
Operational voltage (Ue) | 90% of voltage rating @ 3000 m (9840 ft) altitude | Wire temperature rating | Al or Cu 75 °C |
Storage temperature | -40 °F | Depth | 103.5 mm |
Width | 210 mm | Device construction | Built-in device fixed built-in technique |
Height | 268 mm | Factory option | 3 NO/NC auxiliary + 1 alarm, 24V AC/DC |
Vibration | 2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G | Mechanical life operations | 20000 /h |
Weight | 9.852 | Degree of protection (IP) | IP40 |
DIN rail (top hat rail) mounting optional | True | Suitable for DIN rail (top hat rail) mounting | False |
Type of electrical connection of main circuit | Screw connection | Position of connection for main current circuit | Front side |
Motor drive optional | True | With switched-off indicator | False |
Motor drive integrated | False | Protection type | T/M-adjustable thermal/adjustable magnetic TMA |
Rated service short-circuit breaking capacity (Ics) | IEC 60947-2: 75% Icu @ 750V DC, 3-poles in series, thermal-magnetic trip units only | Rated ultimate short-circuit breaking capacity (Icu) | IEC 60947-2: 80kA @ 440V AC, 50/60 Hz |
Interrupting rating | 50kA @ 600V DC, 3-pole in series, thermal-magnetic trip only per NEMA, UL, CSA | Electrical life cycle | 7000 (600...630 A)/5000 (800 A) @ 415V AC |
Thermal trip rating, max | 600 A @ ambient temperature 40 °C | Insulation voltage (Ui) | Rated 1000V per IEC |
Watt loss | Thermal magnetic type: 90 W | Voltage for reverse-fed circuit breaker, max | 690V AC per IEC |
Magnetic trip current (Im) | 3000 A | Thermal trip current (Ir) | 420 A |
Current range | 80% MCCB | Frame size | 800 A |
Rated impulse withstand voltage (Uimp) | 8 kV | Type of control element | Toggle |
Rated permanent current Iu | 600 A | Complete device with protection unit | True |
Integrated earth fault protection | False | With integrated under voltage release | False |
Number of auxiliary contacts as change-over contact | 3 | Number of poles | 3 |