Rockwell Automation 140G-M0F3-D80-Z1

Selling Points

  • 11. High Interrupting Capacity: The Allen Bradley 140G-M0F3-D80-Z1 features a high interrupting capacity of 100 kAIC, ensuring reliable operation under high fault currents.;
  • 22. Robust Design: Designed for industrial electrical systems, this circuit breaker is built to withstand harsh environments and maintain performance over time.;
  • 33. Certified for Safety: Certified with CSA, China CCC, CE, UL, and Eurasion Economic Community certifications, ensuring compliance with international safety standards.;
  • 44. Minimal Mounting Footprint: The compact design of the 140G-M0F3-D80-Z1 allows for minimal mounting footprint, making it ideal for space-constrained applications.;
  • 55. Versatile Application: Suitable for both three-phase and single-phase systems, as well as DC power systems and systems with neutral conductors, providing flexibility in various industrial settings.
Product Details
140G-M0F3-D80-Z1
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
36.322
Dimension Width
30.48
Lead Time
23
Dimension Height
29.21
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104 °F
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Al or Cu 75 °C
Storage temperature
-40 °F
Depth
103.5 mm
Width
210 mm
Device construction
Built-in device fixed built-in technique
Height
268 mm
Factory option
None
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
20000 /h
Weight
9.625
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
True
Suitable for DIN rail (top hat rail) mounting
False
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
True
With switched-off indicator
False
Motor drive integrated
False
Protection type
T/M-adjustable thermal/adjustable magnetic TMA
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 75% Icu @ 750V DC, 3-poles in series, thermal-magnetic trip units only
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 80kA @ 440V AC, 50/60 Hz
Interrupting rating
50kA @ 600V DC, 3-pole in series, thermal-magnetic trip only per NEMA, UL, CSA
Electrical life cycle
7000 (600...630 A)/5000 (800 A) @ 415V AC
Thermal trip rating, max
800 A @ ambient temperature 40 °C
Insulation voltage (Ui)
Rated 1000V per IEC
Watt loss
Thermal magnetic type: 93 W
Voltage for reverse-fed circuit breaker, max
690V AC per IEC
Magnetic trip current (Im)
4000 A
Thermal trip current (Ir)
560 A
Current range
100% MCCB
Frame size
800 A
Rated impulse withstand voltage (Uimp)
8 kV
Type of control element
Toggle
Rated permanent current Iu
800 A
Complete device with protection unit
True
Integrated earth fault protection
False
With integrated under voltage release
False
Number of poles
3

Specifications may be subject to change without notice