Rockwell Automation 140G-M0I3-D60-SD

Selling Points

  • 11. High Interrupting Capacity: The Allen-Bradley 140G-M0I3-D60-SD is designed to handle high fault currents, ensuring it can interrupt up to 100 kA at 480V, making it suitable for demanding industrial applications.;
  • 22. Electrical Surge Protection: Equipped with high-instability and ground fault protection, this circuit breaker safeguards against electrical surges and short circuits, ensuring the reliability of your electrical system.;
  • 33. UL Listed for Reliability: Certified by UL, this product meets stringent safety standards, providing assurance of its reliability and performance in various industrial settings.;
  • 44. Compact Design: With a compact design, the 140G-M0I3-D60-SD fits seamlessly into your electrical panel, minimizing space requirements while maximizing functionality.;
  • 55. Versatile Application: Suitable for a wide range of applications including three-phase power systems, single-phase systems, and DC power systems, this circuit breaker is versatile and adaptable to various industrial needs.
Product Details
140G-M0I3-D60-SD
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
0.0
Dimension Width
0.0
Lead Time
23
Dimension Height
0.0
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104 °F
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Al or Cu 75 °C
Storage temperature
-40 °F
Depth
103.5 mm
Width
210 mm
Device construction
Built-in device fixed built-in technique
Height
268 mm
Factory option
Shunt-trip, 110...127V AC @ 110...125V DC
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
20000 /h
Weight
0.999
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
True
Suitable for DIN rail (top hat rail) mounting
False
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
True
With switched-off indicator
False
Motor drive integrated
False
Protection type
Electronic LSIG-long and short time, high instantaneous, ground fault
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 75% Icu @ 750V DC, 3-poles in series, thermal-magnetic trip units only
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 80kA @ 440V AC, 50/60 Hz
Interrupting rating
50kA @ 600V DC, 3-pole in series, thermal-magnetic trip only per NEMA, UL, CSA
Operating current (In), max
600A @ 40°C (104 °F) per UL
Protection type—Electronic S (short time trip units)
I2 = 0.6...10 x In (360...6000 A), t2 = 0.05, 0.1, 0.25, 0.5 s
Protection type—Electronic G (ground fault trip units)
I4 = 0.2...1 x In (120...600 A), t4 = 0.1, 0.2, 0.4, 0.8 s
Protection type—Electronic L (long time trip units)
I1 = 0.4...1 x In (240...600 A), t1 = 3, 6, 12, 18 s
Electrical life cycle
7000 (600...630 A)/5000 (800 A) @ 415V AC
Insulation voltage (Ui)
Rated 1000V per IEC
Protection type—Electronic I (instantaneous trip units)
I3 = 900...7200 A
Voltage for reverse-fed circuit breaker, max
690V AC per IEC
Current range
80% MCCB
Frame size
800 A
Rated impulse withstand voltage (Uimp)
8 kV
Type of control element
Toggle
Rated permanent current Iu
600 A
Complete device with protection unit
True
Integrated earth fault protection
True
With integrated under voltage release
False
Number of poles
3

Specifications may be subject to change without notice