  • 11. Robust Protection: The Allen-Bradley 140G-M5F3-D60 circuit breaker provides comprehensive protection against overloads, short circuits, and ground faults, ensuring the safety and reliability of your electrical system.;
  • 22. Thermal-Magnetic Design: Equipped with a thermal-magnetic design, this circuit breaker offers adjustable thermal and magnetic trip units, providing customizable protection settings to meet your specific needs.;
  • 33. High Interrupting Capacity: With an interrupting rating of 50kA at 480V AC, this circuit breaker can handle high short-circuit currents, making it suitable for demanding applications.;
  • 44. Operational Flexibility: Designed to operate at altitudes up to 3000 meters (9840 feet), this circuit breaker maintains its performance and reliability even in challenging environments.;
  • 55. Durable Construction: Built with a durable frame size of 800A and rated for 600A at ambient temperature 40°C, this circuit breaker is designed to withstand the rigors of continuous operation while ensuring long-term reliability.
Product Details
140G-M5F3-D60-SC
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
37.973
Dimension Width
31.75
Lead Time
15
Dimension Height
29.464
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104 °F
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Al or Cu 75 °C
Storage temperature
-40 °F
Depth
103.5 mm
Width
210 mm
Device construction
Built-in device fixed built-in technique
Height
268 mm
Factory option
Shunt-trip, 480...525V AC
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
20000 /h
Weight
9.675
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
True
Suitable for DIN rail (top hat rail) mounting
False
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
True
With switched-off indicator
False
Motor drive integrated
False
Protection type
T/M-adjustable thermal/adjustable magnetic TMA
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 75% Icu @ 750V DC, 3-poles in series, thermal-magnetic trip units only
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 85kA @ 220...230V AC, 50/60 Hz
Interrupting rating
50kA @ 480V AC, 50/60 Hz per NEMA, UL, CSA
Electrical life cycle
7000 (600...630 A)/5000 (800 A) @ 415V AC
Thermal trip rating, max
600 A @ ambient temperature 40 °C
Insulation voltage (Ui)
Rated 1000V per IEC
Watt loss
Thermal magnetic type: 90 W
Voltage for reverse-fed circuit breaker, max
690V AC per IEC
Magnetic trip current (Im)
3000 A
Thermal trip current (Ir)
420 A
Current range
80% MCCB
Frame size
800 A
Rated impulse withstand voltage (Uimp)
8 kV
Type of control element
Toggle
Rated permanent current Iu
600 A
Complete device with protection unit
True
Integrated earth fault protection
False
With integrated under voltage release
False
Number of poles
3

Specifications may be subject to change without notice