Rockwell Automation 140G-M5H3-D80-CJ

Selling Points

  • 11. High Current Rating: The 140G-M5H3-D80-CJ supports an impressive 800A current rating, making it suitable for high-power applications in industrial settings.;
  • 22. Enhanced Interrupting Capacity: With an interrupting capacity of 50kA at 480V AC, this circuit breaker provides robust protection against short circuits, ensuring the safety of equipment and personnel.;
  • 33. Electronic LSI Protection: Equipped with electronic LSI (Long and Short Time) protection, this breaker offers high instantaneous and long-time protection against electrical faults, ensuring reliable operation.;
  • 44. Durable Construction: Built with a durable design, the 140G-M5H3-D80-CJ is engineered to withstand harsh industrial environments, including high temperatures and altitudes.;
  • 55. IP40 Protection: Featuring an IP40 rating, this circuit breaker provides protection against solid particles and dust, ensuring it operates effectively in various industrial settings.
Product Details
140G-M5H3-D80-CJ
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
29.2
Dimension Width
37.4
Lead Time
23
Dimension Height
31.0
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104 °F
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Al or Cu 75 °C
Storage temperature
-40 °F
Depth
103.5 mm
Width
210 mm
Device construction
Built-in device fixed built-in technique
Height
268 mm
Factory option
3 NO/NC auxiliary + 1 alarm, 24V AC/DC
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
20000 /h
Weight
10.636
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
True
Suitable for DIN rail (top hat rail) mounting
False
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
True
With switched-off indicator
False
Motor drive integrated
False
Protection type
Electronic LSI-long and short time, high instantaneous
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 75% Icu @ 750V DC, 3-poles in series, thermal-magnetic trip units only
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 85kA @ 220...230V AC, 50/60 Hz
Interrupting rating
50kA @ 480V AC, 50/60 Hz per NEMA, UL, CSA
Operating current (In), max
800A @ 50°C (122 ?F) per IEC
Protection type—Electronic S (short time trip units)
I2 = 0.6...10 x In (480...8000 A), t2 = 0.05, 0.1, 0.25, 0.5 s
Protection type—Electronic L (long time trip units)
I1 = 0.4...1 x In (320...800 A), t1 = 3, 6, 9, 18 s
Electrical life cycle
7000 (600...630 A)/5000 (800 A) @ 415V AC
Insulation voltage (Ui)
Rated 1000V per IEC
Protection type—Electronic I (instantaneous trip units)
I3 = 1200...8400 A
Voltage for reverse-fed circuit breaker, max
690V AC per IEC
Current range
80% MCCB
Frame size
800 A
Rated impulse withstand voltage (Uimp)
8 kV
Type of control element
Toggle
Rated permanent current Iu
800 A
Complete device with protection unit
True
Integrated earth fault protection
False
With integrated under voltage release
False
Number of auxiliary contacts as change-over contact
3
Number of poles
3

Specifications may be subject to change without notice