  • 11. High Interrupting Capacity: The 140G-M5H4-D80-AB boasts a 50kA interrupting capacity, making it suitable for applications requiring high short-circuit protection. This ensures the breaker can handle severe electrical surges effectively.;
  • 22. Electronic LSI Protection: Equipped with electronic LSI (long and short time) protection, this circuit breaker provides both instantaneous and delayed protection against overcurrent conditions. This enhances safety and reliability in industrial settings.;
  • 33. Global Application Compatibility: The 140G-M5H4-D80-AB is approved for global applications, meeting standards such as UL, CSA, CCC, and IEC. This ensures it can be used in a wide range of environments worldwide.;
  • 44. Customization Options: This circuit breaker offers a variety of customization options, including different trip units and accessories. This flexibility allows users to tailor the device to their specific application needs.;
  • 55. Compact Design: Despite its high performance, the 140G-M5H4-D80-AB features a compact design, making it suitable for space-constrained installations. Its dimensions and mounting options ensure easy integration into control panels and other electrical systems.
Product Details
140G-M5H4-D80-AB
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
0.0
Dimension Width
0.0
Lead Time
23
Dimension Height
0.0
Quick Turnaround
false
Preferred Availability
false
Repairable
NOT_REPAIRABLE
Ambient temperature without derating
104 °F
Rated uninterrupted current (Iu)
98% of current rating @ 3000 m (9840 ft) altitude
Operational voltage (Ue)
90% of voltage rating @ 3000 m (9840 ft) altitude
Wire temperature rating
Al or Cu 75 °C
Storage temperature
-40 °F
Depth
103.5 mm
Width
280 mm
Device construction
Built-in device fixed built-in technique
Height
268 mm
Factory option
1 NO/NC auxiliary + 1 alarm 400V AC
Vibration
2...13.2 Hz ±1 mm, 13.2...100 Hz ±0.7 G
Mechanical life operations
20000 /h
Weight
0.999
Degree of protection (IP)
IP40
DIN rail (top hat rail) mounting optional
True
Suitable for DIN rail (top hat rail) mounting
False
Type of electrical connection of main circuit
Screw connection
Position of connection for main current circuit
Front side
Motor drive optional
True
With switched-off indicator
False
Motor drive integrated
False
Protection type
Electronic LSI-long and short time, high instantaneous
Rated service short-circuit breaking capacity (Ics)
IEC 60947-2: 75% Icu @ 750V DC, 3-poles in series, thermal-magnetic trip units only
Rated ultimate short-circuit breaking capacity (Icu)
IEC 60947-2: 85kA @ 220...230V AC, 50/60 Hz
Interrupting rating
50kA @ 480V AC, 50/60 Hz per NEMA, UL, CSA
Operating current (In), max
800A @ 50°C (122 ?F) per IEC
Protection type—Electronic S (short time trip units)
I2 = 0.6...10 x In (480...8000 A), t2 = 0.05, 0.1, 0.25, 0.5 s
Protection type—Electronic L (long time trip units)
I1 = 0.4...1 x In (320...800 A), t1 = 3, 6, 9, 18 s
Electrical life cycle
7000 (600...630 A)/5000 (800 A) @ 415V AC
Insulation voltage (Ui)
Rated 1000V per IEC
Protection type—Electronic I (instantaneous trip units)
I3 = 1200...8400 A
Voltage for reverse-fed circuit breaker, max
690V AC per IEC
Current range
80% MCCB
Frame size
800 A
Rated impulse withstand voltage (Uimp)
8 kV
Type of control element
Toggle
Rated permanent current Iu
800 A
Complete device with protection unit
True
Integrated earth fault protection
False
With integrated under voltage release
False
Number of auxiliary contacts as change-over contact
1
Number of poles
4