Rockwell Automation 150-C135NBD

Selling Points

  • 11. Efficient Motor Control: The Allen Bradley 150-C135NBD features advanced operating modes such as soft start and current limit start, which reduce mechanical stress and protect motors from large inrush currents during startup.;
  • 22. Precision Speed Management: With selectable kickstart and dual ramp start modes, this controller provides precise speed management with independent acceleration and deceleration controls, ensuring optimal motor performance.;
  • 33. Reliability and Durability: The IP65 enclosure protection makes the 150-C135NBD suitable for severe settings, protecting it from low-pressure water jets and all-direction particle intrusion.;
  • 44. Versatile Compatibility: The controller operates efficiently over a voltage range of 200-460V AC and has a control voltage span of 100-240V AC, making it adaptable to various industrial configurations.;
  • 55. Advanced Safety Features: The device incorporates auxiliary contact ratings capable of managing 240VAC and has a trip rating of 120% of full load amperes (FLA), ensuring the motor can withstand overcurrent conditions without compromising its structural soundness.
Product Details
150-C135NBD
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
STOCKED
Dimension Length
63.5
Dimension Width
30.988
Lead Time
5
Dimension Height
29.997
Quick Turnaround
false
Preferred Availability
false
Repairable
REPAIRABLE
Pollution degree
2
Altitude
2000 m
EMC immunity levels
Surge transient: per EN/IEC 60947-4-2 per IEC
EMC emission levels
Radiated emission: Class A per IEC
Operating temperature
Open: -5 to 50 °C (23 to 122 °F)
Humidity
5...95% noncondensing
Rated surrounding temperature range without derating
-5 °C
Storage and transportation temperature
-25 °C
Enclosure
Open type
Power pole holes
One M10 x 1.5 diam hole per power pole for load Power Terminals
Number of poles
Equipment is designed for 3-phase only for power circuit
Mounting hole size
7.5 mm
Selectable soft stop
Off, 100%, 200%, or 300% of the start time setting when wired
Selectable initial torque
15%, 25%, 35%, and 65% of locked rotor torque
Selectable kick start - 450% FLA
0, 0.5, 1.0, or 1.5 s
Function
Single direction
Internal bypass
Yes
Tightening torque
0.45...0.9 Nm (4.0...8.0 in-lb) for control terminals
Break
TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Make
TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
Vibration
Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Cable size
0.2...2.5 mm2 (24...14 AWG) for control terminals
Height
443.7 mm (17.47 in)
Depth
205.2 mm (8.08 in)
Width
196.4 mm (7.74 in)
Shock
Opsal: 15 G
Weight
15.997
Degree of protection (IP)
IP2X
Input ON-state current (IN1, IN2)
9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Input ON-state voltage, during start (IN1, IN2)
85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Selectable current limit
150%, 250%, 350%, and 450% of full load current
Input OFF-state voltage (IN1, IN2), max
40V AC @ 17V DC/12V AC for control circuit
Selectable start times
2, 5, 10, 15, 20, 25, or 30 s
Selectable overload trip class
Trip Class 10, 15, or 20
Short circuit protection device performance (SCPD) type
Type 1
Integrated motor overload protection
Yes
Standard controller feature
Soft stop
Rated operational current, max
TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Utilization category
TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Type of contacts
TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Type of control circuit
TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Conventional thermal current (Ith)
TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of current
TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
High capacity available fault current, max
70kA @ 600V, maximum current 400 A time delay Class J or Class L fuse for inside delta connected motors
Number of contacts
TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
Short-circuit protection device list
Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Input OFF-state current
<10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit
Rated control power during start with fan
200mA @ 120V AC/120mA @ 240V AC, 600mA @ 24V AC/DC
Rated operational voltage
250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Insulation voltage
Rated 600V AC per UL/CSA/NEMA for power circuit
Dielectric withstand
2500V AC per IEC for power circuit
Rated impulse voltage
6 kV for power circuit
Overvoltage category
III per IEC for side mount auxiliary contacts
Delta connected motor power, max
75 kW @ 230V AC @ 50Hz, 3-phase
Operating frequency
50/60 Hz per UL/CSA/NEMA for power circuit
Repetitive peak voltage
1400V per UL/CSA/NEMA for power circuit
DV/DT protection
1000V/μs for power circuit
Controller type
SMC-3
Fan power rating
20 VA
Rated control supply voltage at AC 60 Hz
100
Rated control supply voltage at AC 50 Hz
100
Rated operating voltage Ue
200
Voltage type for actuating
AC/DC
With display
No
Product Family
SMC-3

Specifications may be subject to change without notice