Product Model
150-C135NCD

Selling Points
- 11. Efficient Motor Management: The Allen-Bradley 150-C135NCD SMC-3 Smart Motor Controller is designed to manage standard squirrel-cage induction motors efficiently, ensuring optimal performance in various industrial applications.;
- 22. Advanced Operational Modes: This controller features an array of operational modes including Soft Start, Current Limit Start, Selectable Kickstart, and Soft Stop, enhancing both performance and flexibility in motor control.;
- 33. Programmable Overload Protection: With programmable electronic motor overload protection and selectable overload trip classes, the controller protects against motor damage, offering a selection between automatic and manual trip reset modes.;
- 44. Versatile Compatibility: The controller supports input voltages from 100-600V AC and operates within a frequency range of 50-60 Hz, making it suitable for use at altitudes up to 2000 meters and in various environmental conditions.;
- 55. Reliability and Durability: Housed in an open-type enclosure, the Allen-Bradley 150-C135NCD SMC-3 Smart Motor Controller is built to withstand operational temperatures ranging from 23-104 °F and storage temperatures from -13-185 °F, ensuring reliable operation in diverse settings.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | NON_STOCKED | Dimension Length | 66.04 |
Dimension Width | 35.56 | Lead Time | 10 |
Dimension Height | 35.56 | Quick Turnaround | false |
Preferred Availability | false | Repairable | REPAIRABLE |
Pollution degree | 2 | Altitude | 2000 m |
EMC immunity levels | Surge transient: per EN/IEC 60947-4-2 per IEC | EMC emission levels | Radiated emission: Class A per IEC |
Operating temperature | Open: -5 to 50 °C (23 to 122 °F) | Humidity | 5...95% noncondensing |
Rated surrounding temperature range without derating | -5 °C | Storage and transportation temperature | -25 °C |
Enclosure | Open type | Power pole holes | One M10 x 1.5 diam hole per power pole for load Power Terminals |
Number of poles | Equipment is designed for 3-phase only for power circuit | Mounting hole size | 7.5 mm |
Selectable soft stop | Off, 100%, 200%, or 300% of the start time setting when wired | Selectable initial torque | 15%, 25%, 35%, and 65% of locked rotor torque |
Selectable kick start - 450% FLA | 0, 0.5, 1.0, or 1.5 s | Function | Single direction |
Internal bypass | Yes | Tightening torque | 0.45...0.9 Nm (4.0...8.0 in-lb) for control terminals |
Break | TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts | Make | TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts |
Vibration | Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement | Cable size | 0.2...2.5 mm2 (24...14 AWG) for control terminals |
Height | 443.7 mm (17.47 in) | Depth | 205.2 mm (8.08 in) |
Width | 196.4 mm (7.74 in) | Shock | Opsal: 15 G |
Weight | 14.969 | Degree of protection (IP) | IP2X |
Input ON-state current (IN1, IN2) | 9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit | Input ON-state voltage, during start (IN1, IN2) | 85V AC @ 19.2V DC/19.2V AC minimum for control circuit |
Selectable current limit | 150%, 250%, 350%, and 450% of full load current | Input OFF-state voltage (IN1, IN2), max | 40V AC @ 17V DC/12V AC for control circuit |
Selectable start times | 2, 5, 10, 15, 20, 25, or 30 s | Selectable overload trip class | Trip Class 10, 15, or 20 |
Short circuit protection device performance (SCPD) type | Type 1 | Integrated motor overload protection | Yes |
Standard controller feature | Soft stop | Rated operational current, max | TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts |
Utilization category | TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts | Type of contacts | TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts |
Type of control circuit | TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts | Conventional thermal current (Ith) | TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts |
Type of current | TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts | High capacity available fault current, max | 70kA @ 600V, maximum current 400 A time delay Class J or Class L fuse for inside delta connected motors |
Number of contacts | TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts | Short-circuit protection device list | Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L |
Input OFF-state current | <10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit | Rated control power during start with fan | 200mA @ 120V AC/120mA @ 240V AC, 600mA @ 24V AC/DC |
Rated operational voltage | 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts | Insulation voltage | Rated 600V AC per UL/CSA/NEMA for power circuit |
Delta connected motor current | 59...234A @ 500/575V AC, 3-phase | Dielectric withstand | 2500V AC per IEC for power circuit |
Rated impulse voltage | 6 kV for power circuit | Overvoltage category | III per IEC for side mount auxiliary contacts |
Line connected motor power, max | 90 kW @ 500V AC @ 50Hz, 3-phase | Operating frequency | 50/60 Hz per UL/CSA/NEMA for power circuit |
Repetitive peak voltage | 1600V per UL/CSA/NEMA for power circuit | DV/DT protection | 1000V/μs for power circuit |
Controller type | SMC-3 | Fan power rating | 20 VA |
Rated control supply voltage at AC 60 Hz | 100 | Rated control supply voltage at AC 50 Hz | 100 |
Rated operating voltage Ue | 200 | Voltage type for actuating | AC/DC |
With display | No | Product Family | SMC-3 |
Specifications may be subject to change without notice