Product Model
150-C19NCR

Selling Points
- 11. Reliable Operation: The Allen Bradley 150-C19NCR ensures consistent and reliable motor operation, reducing downtime and increasing overall efficiency.;
- 22. Precise Control: With its advanced microprocessor-based design, this smart motor controller offers precise control over motor performance, ensuring optimal results in your industrial applications.;
- 33. Versatile Compatibility: Compatible with both 50Hz and 60Hz frequencies, the 150-C19NCR can be easily integrated into a wide range of industrial settings, from manufacturing to heavy machinery.;
- 44. Easy Installation: Designed for straightforward installation, the 150-C19NCR simplifies the process of setting up your motor control system, saving you time and resources.;
- 55. Durable Construction: Built with high-quality components, the Allen Bradley 150-C19NCR is designed to withstand the demands of industrial environments, providing long-lasting performance and durability.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Dimension Unit | CM | Weight Unit | KG |
Stock Status | NON_STOCKED | Dimension Length | 18.001 |
Dimension Width | 17.501 | Lead Time | 5 |
Dimension Height | 8.999 | Quick Turnaround | false |
Preferred Availability | false | Repairable | NOT_REPAIRABLE |
Enclosure | Open type | Number of poles | Equipment is designed for 3-phase only for power circuit |
Mounting hole size | 4.6 mm | Pollution degree | 2 |
Altitude | 2000 m | EMC immunity levels | Surge transient: per EN/IEC 60947-4-2 per IEC |
EMC emission levels | Radiated emission: Class A per IEC | Operating temperature | Open: -5 to 50 °C (23 to 122 °F) |
Humidity | 5...95% noncondensing | Rated surrounding temperature range without derating | -5 °C |
Storage and transportation temperature | -25 °C | Steady state heat dissipation | 15 W |
Selectable soft stop | Off, 100%, 200%, or 300% of the start time setting when wired | Selectable initial torque | 15%, 25%, 35%, and 65% of locked rotor torque |
Selectable kick start - 450% FLA | 0, 0.5, 1.0, or 1.5 s | Function | Single direction |
Internal bypass | Yes | Tightening torque | 2.3...3.4 Nm (30 in-lb) for line power terminals, 4.0 Nm (35 in-lb) if 25 mm2 (4 AWG) wire in top terminal for line power terminal |
Break | TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts | Make | TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts |
Vibration | Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement | Cable size | 2.5...25 mm2 (14...4 AWG) for line power terminals |
Height | 139.7 mm (5.5 in) | Depth | 110 mm (4.33 in) |
Width | 44.8 mm (1.76 in) | Shock | Opsal: 15 G |
Weight | 0.9 | Degree of protection (IP) | IP2X |
Input ON-state current (IN1, IN2) | 9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit | Rated control power during start without fan | 205mA @ 120V AC/145mA @ 240V AC, 705mA @ 24V DC/580mA @ 24V AC |
Input ON-state voltage, during start (IN1, IN2) | 85V AC @ 19.2V DC/19.2V AC minimum for control circuit | Selectable current limit | 150%, 250%, 350%, and 450% of full load current |
Input OFF-state voltage (IN1, IN2), max | 40V AC @ 17V DC/12V AC for control circuit | Selectable start times | 2, 5, 10, 15, 20, 25, or 30 s |
Selectable overload trip class | Trip Class 10, 15, or 20 | Short circuit protection device performance (SCPD) type | Type 1 |
Integrated motor overload protection | Yes | Rated control supply voltage at DC | 24 V |
Standard available fault current, max | 5 kA @ maximum standard fuse 70 A for line device opsal current rating | Standard controller feature | Soft stop |
Rated operational current, max | TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts | Utilization category | TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts |
Type of contacts | TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts | Type of control circuit | TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts |
Conventional thermal current (Ith) | TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts | Type of current | TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts |
High capacity available fault current, max | 69kA @ 600V, maximum current 70 A time delay Class J or Class L fuse for inside delta connected motors | Number of contacts | TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts |
Short-circuit protection device list | Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L | Input OFF-state current | <10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit |
Rated control power during start with fan | 215mA @ 120V AC/180mA @ 240V AC, 800mA @ 24V DC/660mA @ 24V AC | Rated operational voltage | 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts |
Insulation voltage | Rated 600V AC per UL/CSA/NEMA for power circuit | Delta connected motor current | 10.9...32.8A @ 500/575V AC, 3-phase |
Line connected motor current | 6.3...19A @ 500/575V AC, 3-phase | Dielectric withstand | 2500V AC per IEC for power circuit |
Rated impulse voltage | 6 kV for power circuit | Overvoltage category | III per IEC for side mount auxiliary contacts |
Delta connected motor power, max | 7.5...30Hp @ 575V AC, 60 Hz, 3-phase | Line connected motor power, max | 7.5...15Hp @ 575V AC, 60 Hz, 3-phase |
Operating frequency | 50/60 Hz per UL/CSA/NEMA for power circuit | Repetitive peak voltage | 1600V per UL/CSA/NEMA for power circuit |
DV/DT protection | 1000V/μs for power circuit | Controller type | SMC-3 |
Overload current | 6.3 A | Rated control supply voltage at AC 60 Hz | 24 V |
Rated control supply voltage at AC 50 Hz | 24 V | Rated operating voltage Ue | 200 |
Voltage type for actuating | AC/DC | With display | No |
Product Family | SMC-3 |
Specifications may be subject to change without notice