Rockwell Automation 150-C251NCR

Selling Points

  • 11. Advanced Soft Starting Features: The Allen Bradley 150-C251NCR offers four modes of operation: Soft Start, Current Limit Start, Kick Start, and Soft Stop, ensuring smooth and controlled motor startup and shutdown.;
  • 22. Enhanced Safety Features: Equipped with an integral bypass and overload protection, this controller ensures the motor and its components are safeguarded against overloads and short circuits.;
  • 33. Comprehensive Diagnostics: The controller includes an LED display that indicates various faults such as overload, overtemperature, phase reversal, phase loss/open load, phase imbalance, short circuit, and test status.;
  • 44. Versatile Compatibility: Compatible with delta connections and designed for use in industrial environments with a pollution level no higher than Pollution 2 (as defined in the EN / IEC0664-1 publication), making it suitable for a wide range of applications.;
  • 55. Reliable Performance: The 150-C251NCR has an ESD immunity of 6 kV for contact discharges and 8 kV for air discharges, ensuring reliable performance in harsh industrial environments.
Product Details
150-C251NCR
Rockwell Automation

Technical Specifications

Detailed engineering parameters based on manufacturer documentation

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
NON_STOCKED
Dimension Length
63.805
Dimension Width
30.81
Lead Time
22
Dimension Height
33.604
Quick Turnaround
false
Preferred Availability
false
Repairable
REPAIRABLE
Enclosure
Open type
Power pole holes
Two M10 x 1.5 diam holes per power pole for load power terminals
Number of poles
Equipment is designed for 3-phase only for power circuit
Mounting hole size
11.5 mm
Pollution degree
2
Altitude
2000 m
EMC immunity levels
Surge transient: per EN/IEC 60947-4-2 per IEC
EMC emission levels
Radiated emission: Class A per IEC
Operating temperature
Open: -5 to 50 °C (23 to 122 °F)
Humidity
5...95% noncondensing
Rated surrounding temperature range without derating
-5 °C
Storage and transportation temperature
-25 °C
Steady state heat dissipation
147 W
Selectable soft stop
Off, 100%, 200%, or 300% of the start time setting when wired
Selectable initial torque
15%, 25%, 35%, and 65% of locked rotor torque
Selectable kick start - 450% FLA
0, 0.5, 1.0, or 1.5 s
Function
Single direction
Internal bypass
Yes
Tightening torque
0.45...0.9 Nm (4.0...8.0 in-lb) for control terminals
Break
TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Make
TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
Vibration
Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Cable size
0.2...2.5 mm2 (24...14 AWG) for control terminals
Height
560 mm (22.05 in)
Depth
265.3 mm (10.45 in)
Width
225 mm (8.86 in)
Shock
Opsal: 15 G
Weight
30.132
Degree of protection (IP)
IP2X
Input ON-state current (IN1, IN2)
9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Input ON-state voltage, during start (IN1, IN2)
85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Selectable current limit
150%, 250%, 350%, and 450% of full load current
Input OFF-state voltage (IN1, IN2), max
40V AC @ 17V DC/12V AC for control circuit
Selectable start times
2, 5, 10, 15, 20, 25, or 30 s
Selectable overload trip class
Trip Class 10, 15, or 20
Short circuit protection device performance (SCPD) type
Type 1
Integrated motor overload protection
Yes
Rated control supply voltage at DC
24 V
Standard available fault current, max
18 kA @ maximum standard fuse 700 A for line device opsal current rating
Standard controller feature
Soft stop
Rated operational current, max
TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Utilization category
TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Type of contacts
TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Type of control circuit
TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Conventional thermal current (Ith)
TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of current
TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
High capacity available fault current, max
70kA @ 600V, maximum current 800 A time delay Class J or Class L fuse for inside delta connected motors
Number of contacts
TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
Short-circuit protection device list
Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Input OFF-state current
<10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit
Rated control power during start with fan
200mA @ 120V AC/120mA @ 240V AC, 600mA @ 24V AC/DC
Rated operational voltage
250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Insulation voltage
Rated 600V AC per UL/CSA/NEMA for power circuit
Delta connected motor current
145...435A @ 500/575V AC, 3-phase
Line connected motor current
84...251A @ 500/575V AC, 3-phase
Dielectric withstand
2500V AC per IEC for power circuit
Rated impulse voltage
6 kV for power circuit
Overvoltage category
III per IEC for side mount auxiliary contacts
Delta connected motor power, max
315 kW @ 500V AC @ 50Hz, 3-phase
Line connected motor power, max
90...160 kW @ 500V AC @ 50Hz, 3-phase
Operating frequency
50/60 Hz per UL/CSA/NEMA for power circuit
Repetitive peak voltage
1600V per UL/CSA/NEMA for power circuit
DV/DT protection
1000V/μs for power circuit
Controller type
SMC-3
Overload current
84 A
Fan power rating
40 VA
Rated control supply voltage at AC 60 Hz
24 V
Rated control supply voltage at AC 50 Hz
24 V
Rated operating voltage Ue
200
Voltage type for actuating
AC/DC
With display
No
Product Family
SMC-3

Specifications may be subject to change without notice